2017-30 Amending City Code Chapter 67.1 Floodplain Protection Provisions
COD
>
City Clerk
>
ORDINANCES
>
2017
>
2017-30 Amending City Code Chapter 67.1 Floodplain Protection Provisions
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2017 4:02:30 PM
Creation date
7/18/2017 4:02:25 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2017-30
Res Ord Title
Amending City Code Chapter 67.1 Floodplain Protection provisions
Department
Planning
Approved Date
6/5/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C. The interior grade of the crawlspace below the flood protection <br /> elevation must not be more than two (2) feet below the lowest <br /> adjacent exterior grade; <br /> d. The interior height of the crawlspace measured from the interior <br /> grade of the crawl to the top of the foundation wall must not <br /> exceed four(4) feet at any point; <br /> e. An adequate drainage system must be installed to remove <br /> floodwaters from the interior area of the crawlspace within a <br /> reasonable period of time after a flood event; <br /> f. Portions of the building below the flood protection elevation <br /> must be constructed with materials resistant to flood damage; <br /> and, <br /> g. Utility systems within the crawlspace must be elevated above <br /> the flood protection elevation. <br /> C. Non-Residential Buildings may be structurally dry floodproofed (in lieu of elevation) <br /> provided a licensed professional engineer or architect certifies that: <br /> i. The structure and attendant utilities located below the flood protection <br /> elevation are watertight and capable of resisting the effects of the base flood; <br /> ii. The building design accounts for flood velocities, duration, rate of rise, <br /> hydrostatic and hydrodynamic forces,the effects of buoyancy, and the impact <br /> from debris and ice; <br /> iii. Floodproofing measures shall be incorporated into the building design and <br /> fully operable without human intervention and without an outside source of <br /> electricity; and, <br />