Laserfiche WebLink
(ii) The area below the flood protection elevation shall <br /> be used solely for parking or building access and not <br /> later modified or occupied as habitable space; or, <br /> (iii) In lieu of the above criteria. Aall design methods <br /> intended to comply with these requirements shall be <br /> certified by a licensed professional engineer or <br /> architect. <br /> e. The foundation and supporting members shall be anchored, <br /> designed, and certified by a licensed engineer, to minimize <br /> exposure to hydrodynamic forces such as current, waves, ice, <br /> and floating debris. <br /> iii. An existing building may have a crawlspace located below the flood <br /> protection elevation provided that the following conditions are met: <br /> a. The building must be designed and eei4ified by a licensed <br /> engineer and be adequately anchored to resist floatation, <br /> collapse, and lateral movement of the structure resulting from <br /> hydrodynamic and hydrostatic loads, including the effects of <br /> buoyancy; <br /> b. Any enclosed area below the flood protection elevation shall <br /> have openings that equalize hydrostatic pressures by allowing <br /> for the automatic entry and exit of floodwaters. A minimum of <br /> one opening on each wall having a total net area of not less than <br /> one(1)square inch per one(1) square foot of enclosed area. The <br /> openings shall be no more than one (1) foot above final grade; <br /> 1 <br />