Laserfiche WebLink
(number of connectors x 0.50} + <br /> (number of splices x 0.10) <br /> (2) At 1550 nm: (0.25 dB/km x km of cable) + <br /> (number af connectars x 0.50) + <br /> (number of splices x 0.10} <br /> b. The C1TY'S lass 1 attenuation abjective for each fiber optic splice is 0.10 dB <br /> (with a 0.15 upper limit) when measured in one direction with an OTDR test <br /> set{excluding cannector loss, which is typically Q.54 dB per connector} <br /> 3. Out-of-Spec Testing. Test res�alts outside the specifications iisted above shall be noted, <br /> but shalt not preclude acceptance of a fiber if the au#-of-spec condition does not affect <br /> transmission capability(based on use af then-prevailing telecammunications industry <br /> standards applicable ta equipment generaily used with the relevant type of fiber) or <br /> create a significant possibility of an outage. <br /> 23 <br />