My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023-91 Ordinance Amending City Code Chapter 26 Heating, Air Conditioning and Refrigeration Contractors
COD
>
City Clerk
>
ORDINANCES
>
2023
>
2023-91 Ordinance Amending City Code Chapter 26 Heating, Air Conditioning and Refrigeration Contractors
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2023 11:42:36 AM
Creation date
12/21/2023 11:42:34 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2023-91
Res Ord Title
2023-91 Ordinance Amending City Code Chapter 26 Heating, Air Conditioning and Refrigeration Contractors
Department
Econ and Com Dev
Approved Date
12/18/2023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chapter 67 — Buildina Code <br /> International Building Code <br /> This code applies to all buildings except detached one-and two-family dwellings and townhouses up to <br /> three stories. <br /> New in the 2021 IBC: <br /> • Puzzle rooms(escape rooms)are now defined and regulated as special amusement areas, <br /> requiring compliance with Section 411 and special means of egress requirements. <br /> • For the purposes of determining the allowable number of control areas in a building,each portion <br /> separated by one or more fire walls is now considered as a separate building. <br /> • In Group E occupancies,enhanced classroom acoustics in compliance with ICC A117.1 are to be <br /> provided in all classrooms having of volume of 20,000 cubic feet or less. <br /> • The requirements for metal composite materials and systems(MGM)installed on the exterior <br /> walls of Types I, ll, 111 and IV construction were simplified and sprinkler allowances were deleted <br /> • The use of intermodal shipping containers as buildings is now specifically addressed through <br /> provisions intended to supplement existing applicable IBC requirements. <br /> • Automatic sprinkler protection is now required in Group S-2 open parking garages where any fire <br /> area exceeds 48,000 square feet. <br /> • The 2017 edition of ICC A117.1 was adopted. <br /> • Parapets of a minimum height are now required for aggregate-surfaced roofs to prevent blow-off. <br /> • Mixed occupancy buildings with assembly spaces are placed in Risk Category III when the total <br /> public assembly occupant load is greater than 2500 people. <br /> • The 2021 IBC snow map is updated to match ASCE 7-16 snow maps by adding a reference to <br /> ASCE 7 snow tables in states with large case study areas. <br /> • Secondary rain loads are updated to be consistent with ASCE 7. <br /> • Special inspection requirements were added to address the anchorage and connection of mass <br /> timber structural elements. <br /> • Installation of firestop,fire-resistant joint systems and perimeter fire barrier systems in residential- <br /> use buildings now requires special inspection in Group R fire areas having an occupant load <br /> exceeding 250 people. <br /> • Frost protection for egress doors was added to the foundation requirements. <br /> • ACI standards ACI 117 and ITG 7 were added by reference to provide acceptable tolerances for <br /> concrete construction. <br /> • Three new types of construction (Types IV-A, IV-B, and IV-C)allow mass timber buildings of taller <br /> heights, more stories above grade, and greater allowable areas compared to existing provisions <br /> for heavy timber buildings. <br /> New in the 2018 IBC: <br /> • Accessory storage spaces of any size are now permitted to be classified as part of the occupancy <br /> to which they are accessory. <br /> • New code sections have been introduced addressing medical gas systems and higher education <br /> laboratories. <br /> • Use of fire walls to create separate buildings is now limited to only the determination of <br /> permissible types of construction based on allowable building area and height. <br /> • Where an elevator hoistway door opens into a fire-resistance-rated corridor,the opening must be <br /> protected in a manner to address smoke intrusion into the hoistway. <br /> • The occupant load factor for business uses has been revised to one occupant per 150 square <br /> feet. <br /> • Live loads on decks and balconies increase the deck live load to one and one-half times the live <br /> load of the area served. <br /> • The minimum lateral load that fire walls are required to resist is five pounds per square foot. <br /> • Wind speed maps updated, including maps for the state of Hawaii.Terminology describing wind <br /> speeds has changed again with ultimate design wind speeds now called basic design wind <br /> speeds. <br />
The URL can be used to link to this page
Your browser does not support the video tag.