Laserfiche WebLink
Chapter 67.2 — Residential Building Code <br /> International Residential Code <br /> This comprehensive code comprises all building, plumbing, mechanical, fuel gas and electrical <br /> requirements for one-and two-family dwellings and townhouses up to three stories. <br /> New in the 2021 IRC: <br /> • Braced wall lines must be placed on a physical wall or placed between multiple walls. <br /> • The rated separation for two-family dwellings is 1 hour whether or not a lot line exists between <br /> units. <br /> • Emergency escape and rescue openings require a clear 36-inch-wide path to a public way. <br /> • An engineered design is required for storm shelters. <br /> • A habitable attic is limited to one-half the area of the story below and the dwelling requires <br /> sprinklers. <br /> • Updated Wind Speed maps match IBC and ASCE 7 maps. <br /> • Deck design now considers snow load,tributary area for footing and post height, and guard <br /> details. <br /> • Specific requirements for deck guardrails were added. <br /> • Component and cladding wind pressures in Table R301.2(2)are updated for new design wind <br /> speeds and hip or gable roof profiles. <br /> • Minimum footing size tables are revised to more accurately reflect current practice. <br /> • Cripple wall requirements apply only to exterior cripple walls. <br /> • New appendices for cob construction and 3D printed construction are added. <br /> • A 30 percent reduction of airflow is permitted for balanced ventilation systems. <br /> • Commercial gas cooking appliances are prohibited. <br /> • The head pressure for a water test of DWV systems increased to 10 feet. <br /> • Air vacuum testing is now permitted for plastic piping DWV systems. <br /> • Section P2904 for dwelling sprinklers is expanded to more closely align with NFPA 13D. <br /> • An emergency service disconnect is required in a readily accessible outdoor location. <br /> • A surge-protective device(SPD)is now required at the service panel. <br /> • The number of receptacle outlets required for peninsular and island countertops in kitchens is <br /> determined by the area of the countertop surface. <br /> • GFCI protection is now required for damp and wet locations not included in the other 10 areas <br /> requiring GFCI protection. <br /> New in the 2018 IRC: <br /> • An updated seismic map reflects the most conservative Seismic Design Category(SDC)based <br /> on any soil type and a new map reflects less conservative SDCs when Site Class A, 6 or D is <br /> applicable. <br /> • The townhouse separation provisions now include options for using two separate fire-resistant- <br /> rated walls or a common wall. <br /> • An emergency escape and rescue opening is no longer required in basement sleeping rooms <br /> where the dwelling has an automatic fire sprinkler system and the basement has a second means <br /> of egress or an emergency escape opening. <br /> • The exemption for interconnection of smoke alarms in existing areas has been deleted. <br /> • New girder/header tables have been revised to incorporate the use of#2 Southern Pine in lieu of <br /> #1 Southern Pine. <br /> • New tables address alternative wood stud heights and the required number of full height studs in <br /> high wind areas. <br />