My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023-96 Ordinance Amending City Code Chapter 70 Property Maintenance Code
COD
>
City Clerk
>
ORDINANCES
>
2023
>
2023-96 Ordinance Amending City Code Chapter 70 Property Maintenance Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2023 11:56:21 AM
Creation date
12/21/2023 11:56:20 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2023-96
Res Ord Title
2023-96 Ordinance Amending City Code Chapter 70 Property Maintenance Code
Department
Econ and Com Dev
Approved Date
12/18/2023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> floors and walls are water-tight so as to prevent entry of moisture; (2) all habitable <br /> rooms shall be provided with aggregate glazing of not less than 8%of the floor area <br /> of such rooms; (3)where windows are provided as a means of egress or rescue, the <br /> windows shall have the bottom of the clear opening not more than 44" above the <br /> floor; (4) the minimum net clear opening for the below grade room windows to be <br /> used for egress or rescue shall be 5 square feet; and, (5) means of egress and <br /> emergency escape are provided in accordance with this code. <br /> bUb)(ee) 502.5 by replacing International Plumbing Code with Illinois <br /> Plumbing Code in the first sentence. <br /> cc (fk4 505.1 by replacing the International Plumbing Code with the <br /> Illinois Plumbing Code in the last sentence. <br /> ddd,)(ee) 602.2 by deleting the words "Appendix D of the International <br /> Plumbing Code" and replacing with the words "the Illinois Plumbing Code" <br /> following the words "indicated in". <br /> ee 602.3 by deleting the words "during he period from (Date) to <br /> (Date)" following the words "shall supply heat" and, in the last sentence of number <br /> 1 under Exceptions, by deleting the words "Appendix D of the International <br /> Plumbing Code"and replacing with the words"the Illinois Plumbing Code". <br /> (ffl(gg) 602.4 by deleting the words "during the period from (Date) to <br /> (Date) following the word"heat". <br /> (gg)(M) 604.2 by replacing "NFPA 70" with "National Electrical Code <br /> (NEC)as adopted by the City of Decatur. <br /> (hW(ii)605.1 by adding "as per the National Electrical Code, as adopted by <br /> the City of Decatur"at the end of the sentence. <br /> ii (j) 605.3 by adding "controlled by a wall switch" after the word <br /> luminaire in the first sentence. <br /> LW(kk)702.5 — Number of Exits: In nonresidential buildings, every <br /> occupied story more than six stories above grade shall be provided with not less <br /> than two independent exits. In residential buildings, every story exceeding two <br /> stories above grade shall be provided with not less than two independent exits. In <br /> stories where more than one exit is required, all occupants shall have access to a t <br /> least two exits. Every occupied story which is both totally below grade and greater <br /> than 2,000 square feet shall be provided with not less than two independent exits. <br /> Exception: A single exit is acceptable under any one of the following conditions: <br /> (1) where the building is equipped throughout with an automatic sprinkler system <br /> and an automatic fire detection system with smoke detectors located in all <br /> corridors, lobbies and common areas; (2) where the building is equipped <br /> throughout with an automatic fire detection system and the exit is an approved <br /> smoke proof enclosure or pressurized stairway; (3) where an existing fire escape <br /> conforming to the building code listed in Chapter 8 is provided in addition to the <br /> single exit; and(4)where permitted by the building code listed in Chapter 8. <br /> (kj!�R 704.2 — Smoke Detectors. (1) Every dwelling unit shall be <br /> equipped with at least one approved smoke detector in an operating condition <br /> within 15 feet of every room used for sleeping purposes. The detector shall be <br /> installed on the ceiling and at least 6 inches from any wall, or on a wall located <br /> between 4 and 12 inches from the ceiling measured to the top of the detector. All <br />
The URL can be used to link to this page
Your browser does not support the video tag.