R2024-29 Resolution Accepting the Bid and Authorizing the Execution of a Contract with Reyhan Bros., Inc. dba Sangamo Construction Company and Appropriating Motor Fuel Tax Funds for the West Mound Road Bridge over Stevens Creek
COD
>
City Clerk
>
RESOLUTIONS
>
2024
>
R2024-29 Resolution Accepting the Bid and Authorizing the Execution of a Contract with Reyhan Bros., Inc. dba Sangamo Construction Company and Appropriating Motor Fuel Tax Funds for the West Mound Road Bridge over Stevens Creek
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 11:52:20 AM
Creation date
2/8/2024 3:56:54 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
R2024-09
Res Ord Title
R2024-09 Resolution Accepting the Bid and Authorizing the Execution of a Contract with Reyhan Bros., Inc. dba Sangamo Construction Company and Appropriating Motor Fuel Tax Funds for the West Mound Road Bridge over Stevens Creek
Department
Public Works
Approved Date
2/5/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
General. The repair methods shall be either formed concrete repair or shotcrete. The repair <br /> method shall be selected by the Contractor with the following rules. <br /> (a) Rule 1. For formed concrete repair, a subsequent patch to repair the placement point <br /> after initial concrete placement will not be allowed. As an example, this may occur in a <br /> vertical location located at the top of the repair. <br /> (b) Rule 2. Formed concrete repair shall not be used for overhead applications. <br /> (c) Rule 3. If formed concrete repair is used for locations that have reinforcement with less <br /> than 0.75 in. (19 mm) of concrete cover, the concrete mixture shall contain fly ash or <br /> ground granulated blast-furnace slag at the maximum cement replacement allowed. <br /> (d) Rule 4. Shotcrete shall not be used for any repair greater than 6 in. (150 mm) in depth, <br /> except in horizontal applications, where the shotcrete may be placed from above in one <br /> lift. <br /> (e) Rule 5. Shotcrete shall not be used for column repairs greater than 4 in. (100 mm) in <br /> depth, unless the shotcrete mixture contains 3/8 in. (9.5 mm) aggregate. <br /> NTemporary Shoring or Cribbing. When a temporary shoring or cribbing support system is <br /> required, the Contractor shall provide details and computations, prepared and sealed by an <br /> Illinois licensed Structural Engineer, to the Department for review and approval. When ever <br /> possible the support system shall be installed prior to starting the associated concrete removal. <br /> ■ If no system is specified, but during the course of removal the need for temporary shoring or <br /> cribbing becomes apparent or is directed by the Engineer due to a structural concern, the <br /> Contractor shall not proceed with any further removal work until an appropriate and approved <br /> support system is installed. <br /> Concrete Removal. The Contractor shall provide ladders or other appropriate equipment for the <br /> Engineer to mark the removal areas. Repair configurations will be kept simple, and squared <br /> corners will be preferred. The repair perimeter shall be sawed a depth of 1/2 in. (13 mm) or <br /> less, as required to avoid cutting the reinforcement. Any cut reinforcement shall be repaired or <br /> replaced at the expense of the Contractor. If the concrete is broken or removed beyond the <br /> limits of the initial saw cut, the new repair perimeter shall be recut. The areas to be repaired <br /> shall have all loose, unsound concrete removed completely by the use of chipping hammers, <br /> hydrodemolition equipment, or other methods approved by the Engineer. The concrete removal <br /> shall extend along the reinforcement bar until the reinforcement is free of bond inhibiting <br /> corrosion. Reinforcement bar with 50 percent or more exposed shall be undercut to a depth of <br /> 3/4 in. (19 mm) or the diameter of the reinforcement bar, whichever is greater. <br /> If sound concrete is encountered before existing reinforcement bars are exposed, further <br /> removal of concrete shall not be performed unless the minimum repair depth is not met. <br />