Exhibit A <br /> SCOPE OF WORK <br /> The services to be provided for the Project are as follows: <br /> TELEVISED PIPELINE INSPECTION/SURVEY <br /> A. A color television camera capable of insertion into 100% humidity conditions will be used for this <br /> project. The camera head is capable of panning 2701 and tilting 3600 and the iris, focus and light <br /> source are all remote controlled, to look directly at problem areas, as well as up service <br /> connections. The camera will be transported through the lines on a remote-controlled transporter <br /> at approximately 30 feet per minute, stopping at problem areas to ensure proper logging of data. <br /> B, The data collected, stored and downloaded to the city mainframe will be in a MPEG digital format <br /> compatible with the current City of Decatur Engineering Software. The digital format will allow City <br /> Engineers to observe recorded features and conditions that will assist in the evaluation of the data <br /> collected and become a part of the final report. All inspection crews are PACP Certified. TSI shall <br /> use Granite Net with ESR( module and the scoring module by Cues, Inc. <br /> C. Traffic control and protection for the project shall be in accordance with IDOT Highway Standard <br /> 701606.01. Daytime operations are proposed for the work. <br /> STORM/SANITARY SEWER CLEANING <br /> A. A high velocity sewer cleaning and vacuum combination truck will be used. Cleaning shall be <br /> accomplished by using a pump capable of delivering 80 GPM at 2,500 PSL All debris from the <br /> cleaning process will be removed with the Vac System. The City of Decatur will supply water and <br /> dump site for any solids gathered. <br /> MANHOLE INVESTIGATION <br /> A. A physical/visual investigation of each manhole using all necessary safety equipment. The <br /> investigation will include obtaining all data required to evaluate each manhole for structural <br /> integrity, inflow/infiltration problems, flow characteristics and environmental conditions. Including <br /> all necessary dimensions. <br /> SMOKE/DYE TESTING <br /> A. Insertion of an inert type of smoke bomb of three-minute duration into manholes by means of a <br /> 3.,000 cfm or larger blower. Logging of data including color photos of locations and/or smoke <br /> observed. <br /> B. Application of vegetable-based dye into storm/sanitary systems for investigation of cross <br /> connections and/or sanitary effluent traveling to creeks, rivers and/or lakes, house service and sink <br /> holes. Dye testing is covered under our emergency inspection/survey. <br />