Laserfiche WebLink
Exhibit 2 <br /> The tube will be built by ADM Mechanical. The following design standards will be used as reference for <br /> structural design of this tube: <br /> 1. API—welded steel tanks for oil storage <br /> 2. AISC—spec for design fabrication & erection of structural steel buildings <br /> 3. Building Code—the BOCA National Building Code <br /> 4. ASTM —spec for structural steel <br /> It will be positively connected to two (2) saddle supports on either side of Garfield Avenue. Both saddle <br /> supports will be located on ADM property. The bottom side of the tube will be approximately 38 feet <br /> off the road surface. The top side of the tube will be approximately 49 feet off the road surface. Final <br /> design of the tube will be performed by an Illinois Registered Structural Engineer. <br /> Construction of the tube and placement in the right-of-way should take place in the fall of 2012. ADM <br /> will coordinate with the City of Decatur during this portion of the construction phase. <br /> Legal Location: <br /> Partially located in the NE%, Section 7 <br /> & in the SE%, Section 6, <br /> T.16.N, R.3.E, 3`d PM <br />