2012-47 GRANTING WIND ENERGY SYSTEM PERMIT
COD
>
City Clerk
>
ORDINANCES
>
2012
>
2012-47 GRANTING WIND ENERGY SYSTEM PERMIT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2015 10:51:08 AM
Creation date
8/25/2015 10:51:07 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2012-47
Res Ord Title
GRANTING WIND ENERGY SYSTEM PERMIT - 2410 WEST MOUND ROAD
Department
Development Services
Approved Date
7/16/2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12.15' <br /> General Notec_ <br /> 1. Tower height is approximately 28 feet from the ground to the top of the tower. <br /> TURBINE SUPPORTS <br /> N1.53'14 2. The setbacks for this property are as shown on the site plan. <br /> M LOT 2 COUNTY FAIR <br /> COMMERCIAL/INDUSTRIAL PARK III <br /> 1832/259 q5 3. The sound power level of the turbine is expected to be less than 35 Db at 10 <br /> 30' 0' 30' <br /> mill12 feet away from the turbine during a 30 mph wind. Further dissipation of <br /> ILLINOIS COORDINATE 6 « <br /> SYSTEM EAST ZONE Z. noise w i I I take place i n the remaining 33 feet to the property I I ne. <br /> 10' UTILITY m <br /> EASEMENT N <br /> N 88` 28' 36" E <br /> 13.67' 4. The wind turbine location meets olI ordinance requirements for front ord. <br /> 107.74' (107.86') y <br /> 30' possible utility interference and required setbacks. <br /> s <br /> o <br /> 5. There will be a single wind turbine placed on this property, <br /> w <br /> 20' BUILDING FFE 676.5 <br /> SETBACK N W 6. The single wind turbine will be roof mounted as shown on the attached detotls. <br /> om <br /> N� <br /> 10' UTILITY <br /> EASEMENT o c 7. This wind turbine is designed for a 3 second gust of 140 mph as shown on the <br /> Ln <br /> ~ ~ N attached details. <br /> Z <br /> oO N 88. 46' 28" E 276.50' (276.53') <br /> j B. This wind turbine has on on board monitoring circuit which creates a dynamic <br /> 00 O W <br /> m v 00 / broke for over speed situations. The other broking system is on On/Off switch, <br /> ONN N ' <br /> J M _ 10' UTILITY EASEMENT This wind turbine does not possess a mechonical braking system. The supplier <br /> N ; 30' BUILDING SETBACK <br /> Z 10' BUILDING �, <br /> Y a SETBACK ° states mechonical systems are typically used only on larger commercial <br /> (A `p <br /> M I - �y . "y' �/ �` ��� turbines 1n the l MW or larger range. <br /> o \ h x pF �/ `moi /moi <br /> 11 <br /> z 35" W 2, yi . t1 9. Signage wiII meet the requirements of Item 11 of Sect fon XXXV of Wind Energy <br /> s "� 5, gocK 1N� Systems. <br /> 11 11 IV/ <br /> 10. The tower will not be accessible for unassisted climbing. <br /> n <br /> ti UIILDING �` �ti6 ,� / �� �• % �' LEGEND <br /> SET <br /> 0 1 ,/ / • SET PIN 11. The wind turbine will meet the color and Iighting requirements of Item ll of <br /> PROPOSED 20' a 0ti /// \ �' a FOUND PIN Section XXXV of Wind Energy Systems. <br /> ACCESS EASEMENT �� y0.: Q / Opp // ———— ENTR <br /> // ———— EDGE PAVE <br /> / —E— UTILITY (ELECTRIC) <br /> 12. Soil studies hove not been conducted as a port of this project. <br /> COMM BLDG <br /> GUARDPOST <br /> YS• D� /' /� .0 FLARED END SECT 13. This project is not located within a local Or national historic district, <br /> Y HYDRANT <br /> CULVERT There Is no knowledge of any local landmarks of this location. <br /> ` Y / t TURBINE LOCATION <br /> EXISTING R.O.W. <br /> EXHIBIT A <br /> DRAINAGE STATEMENT <br /> WE. THE UNDERSIGNED RESPECTIVELY A REGISTERED PROFESSIONAL <br /> ENGINEER AND THE OWNER OR OWNERS OF THE LAND SUBDIVIDED HEREBY ��P OF <br /> S , <br /> / / DRILL HOLE OR THE DULY AUTHORIZED ATTORNEY OF SUCH OWNER OR OWNERS, STATE <br /> THAT TO THE BEST OF OUR KNOWLEDGE AND BELIEF THE DRAINAGE OF .p _` ••••• •.��i�j/ij. <br /> SURFACE WATERS WILL NOT BE CHANGED BY THE CONSTRUCTION OF SUCH L P ••••• v / <br /> SUBDIVISION OR ANY PART THEREOF, OR, THAT IF SUCH SURFACE rr',w,\'•'• '.®�h41 <br /> WATER DRAINAGE IS CHANGED. REASONABLE PROVISION HAS BEEN MADE , J:� GREGG L. •.V'c,• SITE LOCATION <br /> FOR THE COLLECTION AND DIVERSION OF SURFACE WATERS INTO PUBLIC <br /> / AREAS, OR DRAINS WHICH THE SUBDIVIDER OR SUBDIVIDERS HAVE A C1~2 <br /> / ���h •a O,� / RIGHT TO USE• AND THAT SUCH SURFACE WATERS WILL BE PLANNED FOR M: FO L I Z LE ;f• <br /> / �1• // / IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING PRACTICES C:7; ;W <br /> SO AS TO REDUCE THE LIKELIHOOD 9 DAMAGE TO THE ADJOINING iVUESJi �R <br /> i <br /> PROPER BECAUSE OF THE CONS�RL 10 0 THE SUBDIVISION.SION. w 7 A '�. /Y tAouNp RD. <br /> 421244 y:� '- > <br /> EXISTING FIRE HYDRANT l%p <br /> DATE '� �I" /v yr�0• <br /> 7� z <br /> 1 1N61 RO 5510NAL ENGINEER > / pROFESSO'-'1^``�\ <br /> LICERSE EXPI Eq NOV. 30, 2013 ��/�A'�l i ( 2p <br /> SITE MAP <br /> OWNER DATE <br /> FILE NAME a USER NAME _$USERS DESIGNED - REVISED - HOMER L F.A. TOTAL SHEET <br /> a C�IAS�'AIN SECTION COUNTY <br /> SFILELS (J 1 DECATUR (sLn4ss-eu4 SITE PLAN FOR WIND GENERATION UNIT RTE. SHEETS NO. <br /> DRAWN - REVISED - CHICA00 07A 71(-0050 CLIFF MASKE <br /> PLOT SCALE=*SCALES CHECKED - REVISED - & ASSOCIATES LLP ROCKFORD (815)499-0050 2410 WEST MOUND ROAD - DECATUR, ILLINOIS 62526 <br /> PLOT OArE =sw,TE• DATE - REVISED - coNsuLr( , ]ITE—SALa BNaeN194-001397 SCALE, SHEET N0. 1 OF 2 SHEETS CONTRACT NO.STA. TO STA. uuNots FEO.Alp vno,rctr <br />