Laserfiche WebLink
'Chapter 67 <br /> (p) Table 508.2.5 Storage rooms greater than 100 sq. ft. shall be separated from <br /> other spaces by one hour fire barriers or have automatic fire suppression system. <br /> (Q) 903.4.2., change "alarm devices shall be provided on the exterior of the <br /> building in an approved location" to "alarm devices shall be provided on the interior and exterior <br /> of the building in approved locations." <br /> 9. FEE. The amount of the fee required to accompany the application for a permit and <br /> to be paid to the City Treasurer shall be determined by the building official as follows: <br /> (a) For all permits other than those particularly specified herein said amount shall <br /> be based upon the value of the proposed work in amounts as follows: <br /> WORK VALUE FEE <br /> $ 0 - $2,000 $2-5 35 <br /> $2,001 - $3,000 $3545 <br /> $3,001 - $5,000 $50 <br /> $5,001 - $1,000,000 $50 plus $5 for each <br /> $1,000 or fraction <br /> thereof over$5,000 <br /> Over $1,000,000 $5,025 plus $4 for each <br /> $10,000 or fraction thereof <br /> over$1,000,000 <br /> (c) For permits to erect new one or two-family residential structures, room <br /> additions to such structures, accessory buildings to such structures, or additions to accessory <br /> structures the amount shall be as follows: <br />