<br /> A combination lead-based paint xisk assessinent:and inspection was.conducted at 680 South.Haworth
<br /> Avenue, Decatur, Illinois 62522 foi fhe Neai We'st Restoration.ancl�Pr'eservation Society, located at 234 � '
<br /> South College, Decatur, IL '62522.-.The risk.assessri;�nt'was conducted on Q�pril 1, 2010 by�James W:� . �
<br /> Sundberg, an Illinois Department of Public Health':(IDPH) �licensed Risk Assessor (License Number L-: . � • �
<br /> 1743). • .. . . . . .. : • � �. � � . . � � . •
<br /> Results . . .. . . . . . . � � . �
<br /> 'Specific focus was given to addressing painted'surfaoes within.the scope�of work for this building.. The � �
<br /> building and its paint are not in good condit'ion:overall..There were a few.areas found.that contain lead : '
<br /> based paint l�azards. , ' . ' . ' • . .:
<br /> � . ➢ Exterior House Exposed:Wood Soffits� �'_. _ ' , _ . ' .'. , : .. .
<br /> � ➢ Exterior House Wall B Wood Awning�and Attached.Components � ' . �. �,. ,
<br /> . . ,, . . . . _
<br /> � . � ➢ Exterior F3ouse Wall B Metal;and:Concrete Stai'r,Cotnponent.s(To Main,and Basement). . ' , � '
<br /> � � ➢ Exterior House Wall B Wood Door.�omponents and ThreshoId . '; � , � '
<br /> . . , . - ' ,. � .. •
<br /> ,s ➢ . Exterior House Wood Window,;Gomponents.and.Interior Window Wells (1VIain and Upper ;,� ,
<br /> Levels) , � . � . . , . . . . . . . . . .. : . . . ... :. .. ' , . . -
<br /> �7 ➢ Exterior House Wall�A Thresholcl , .� . • �. . ; � � . � . ' � '
<br /> � ➢ Exterior House Wa1T D Door.Jambs.and Casings•.� � , � � . ' , .� . ,
<br /> � ➢ All Snrfaces except the Bathroom .# 2 Floor with Lead Dust above the_IDPH Regulatory., � � �
<br /> . Levels . .. • .. . .
<br /> Additional sampling .was performed to.ensure��that�all components:"touched" by."fiiture maintenance . �
<br /> activities would not disturb LBP. Some of:the tested'suifaces tested negative foi:lead'content(below 1'.0 � .
<br /> mg/cmZ using.XRF technology). These surfaces.are not considered to be�lead based.�paint hazards, using ; .� . �
<br /> criter'ia in the Illinois Department of Public Health�Lead Poisoning'Prevention Code(Title�77 Part 845.).
<br /> .. „ . . . . ; � . . .
<br /> . Those surfaces are: . . ' � ' � � � � � ' � . . ' �� � � '.
<br /> Walls around aIl Windows, except those�listed'above.and below� � �. � - �
<br /> Ceilings, except those listed above.and belovy� �.' . . ':�: �.. ' '. ' � ' � .. �' � .
<br /> Interior poor Panels, Jambs,and Casings;.except those:listed above and below: , . • • . . . �
<br /> Baseboards, except those listed a}iove and below•-.' . .' � '- � . . ' " ' ' � ' ' �
<br /> . Cabinets, except those listed above and below :' . . • . _
<br /> i , , • . ., , . I
<br /> I , . . ii
<br /> i ; ' ' . , .� ' ' • . ' '. " , . '
<br /> i . . . . . ' . _ • : . . . . , " . : . .
<br /> � ' . . . ••, � - . .' . . • . . .
<br />
|