My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-62 GRANTING CONDITIONAL USE PERMIT 1096 West Decatur Street
COD
>
City Clerk
>
ORDINANCES
>
2015
>
2015-62 GRANTING CONDITIONAL USE PERMIT 1096 West Decatur Street
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2015 10:50:31 AM
Creation date
11/30/2015 10:50:29 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2015-62
Res Ord Title
GRANTING CONDITIONAL USE PERMIT ROOF TOP CELL TOWER - 1096 WEST DECATUR STREET
Approved Date
11/16/2015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"`�`m ���� '7� <br /> 0 <br /> zr-s�rz• w►Pio RooF connnu3 ti ��, <br /> SYSTEM BY CONIQIN '� <br /> 8'-5" 7" 12'-1 72" PAINTED CONCRETE �NCREIE N �� <br /> •\ N <br /> 3 � <br /> ^ az <br /> PARTITION WALL ASSEMBLY HAS 2 LOCATION RAPID ROOF COAl7N0 ` <br /> 2-HOUR FIRE RATED DESIGN 6" &� �� <br /> (SEE DETAIL#3) N OF RAYCAP SYSTEM BY CONIaIN � o� <br /> CONC� I TYPICAL GEN.ROOM •` o m <br /> CAST IN i ROOF SECTION � o� <br /> O � � WSULATION � Q� 3 x <br /> N � I � ' �U <br /> � s,nrr. � � ��rz�ni�tMnsH�►ni ; �`� <br /> � � , <br /> � aFiu� � vr sH�xocic `, � � <br /> p� � P[R NEC � 318'NUPOLY �� i PAINTED ���TE ; <br /> 3,�„ POWER LTE i i AIR TYPICAL ROOF �� � CONCRETE SEE BUILDINCi � <br /> �------------� � >� <br /> CONDITIONING SECTION , � COVERSHEET oa <br /> UNIT ` FOR FINISH ¢���� <br /> LOCATION ` <br /> o OF RAYCAP 2' 4212" 7�,.n� THIS 3HELTER NOT FOR �F w�o�y <br /> �q � HUMAN HABITATION �� 7y�p A� <br /> � O O Z' 2' Z' 2' SOLID CONCRETE �'�' T��G��T� `u g a x�� <br /> � � ROOM WALL SECTION r <br /> _ '!; ;;: <br /> FIF N ♦ CASTIN � <br /> AIR TYPICAL EQUIPMENT ROOM INSULATION <br /> STANDBY D�ESEL CONOITIONING FLOOR SECTION ��` CONCRETE SION � <br /> LOCATION UNIT i � m d � <br /> GENERATOR WITH UL 142 OF RAYCAP � � <br /> STEEL DOUBLE-WALLED i•i _ _ SEE BUILDING COVER <br /> 211 GAL BASETANK _ ` SHEET FOR FlNISH � <br /> SPILL CONTAINMENT 3/g`NUppLY o 3 � <br /> SYSTEM �.•� 8 <br /> 12'3HEETROCK <br /> • � �� � d�• • NOTE: CONCRETE 1/2'BLUE FOAM 7ypICAI WqLI <br /> � � � GENERAL CONTRACTOR IS RESPONSIBLE FOR SECTION <br /> �� � 2 � INSTALLING ALL EXTERIOR ATTACHMENTS FOR ."�•'�'���-�' <br /> • d � � • GENERATOR(HOODS,MUFFLER,VENT,FILL,ETC.) y � <br /> 4'-0"x T-0"DOOR � • a &� • a � TYPICAL GENERATOR ROOM Z <br /> . � � FLOOR SECTION y � i <br /> • • . '. . TRANSVERSESECTION '> o s o <br /> REFER TO FOUNDATION � • • REFER TO FOUNDATION `L W F e " <br /> DRAWINGS FOR STOOP DETAIL � DRAWINGS FOR STOOP DETAIL N.T.S. � g rc � <br /> � � U <br /> FLOOR PLAN-EQUIPMENT ENCLOSURE 3'-4"x r-o^000R o y a <br /> � SCALE:1/2'�=r-o• VENTILATION SCHEDULE - a <br /> vermunoN � <br /> AREA REMARKS <br /> ROOM PURPOSE NATURAL MECHANICAL <br /> ACTUAL REQUIRE ACTUAL REQUIRED <br /> R13 BATT INSULATION INSTALLED WIRELESS TELEPHONE z ' <br /> FIRST LAYER 5/8"TYPE X GREEN BOARD ON STEEL STUDS; BETVVEEN METAL STUDS EQUIPMENT ENCLOSURE 292.8 S.F. o CFM o CFM 260o CFM o CFM SEE NOTE�. <br /> VERTICALLY ORIENT ON INTERMEDIATE STUDS.MOUNT WITH�t6 1/2"CD PLYWOOD;FASTEN W/10-24 X 1 7/16 PWH (NON-INHA8ITED) <br /> X 1 1/4"DRY WALL SCREWS(P/N 853-11583)8"O!C AROUND WING SCREW(P/N 85415403)AT 12"O/C ALONG LOC. # 313781 <br /> PERIMETER AND 12"O/C INTERMEDIATE STUDS.(OFFSET STUDS AND UPPER&LOWER TRACKS NOTES: <br /> VERTICAL JOINTS ONE STUD SPACE)(OFFSET VERTICAL JOINTS • 1. EQUIPMENT ENCLOSURE IS MANUFACTURED BY FIBREBOND CORPORATION, <br /> ONE STUD SPACE) WALL COVERING:3/8"NUPOLY 1300 DAVENPORT DRIVE,MINDEN,LA,71055. THtS SHEET IS PROVIDED AS M I LLI KI N <br /> GENERATOR ROOM SIDE FIRST LAYER OF GYPSUM BOARD:5/8"TYPE X GYPSUM PIANS.ONLY. REFER TO ACTUAL FIBREBOND DRAWINGS FOR FULL BUILDING U N I VE RS I TY <br /> SECOND LAYER OF USG 5/8"TYPE X FIBER ROCK AQUA TOUGH BOARD;VERTICALLY ORIENT&MOUNT TO PLYWOOD W!#6 2. EPS BOARD INSULATION IS LISTED TO HAVE A FLAME SPREAD OF 25 OR LESS <br /> PANEL;VERTICALLY ORIENT ON INTERMEDIATE STUDS.(OFFSET X 9-5/8"DRYWALL SCREWS(P/N 853-11584)8"O/C AROUND /+ND SMOKE DEVELOPED OF 45o OR LESS WITH A MAXIMUM THICKNESS OF 2 <br /> VERTICAL JOINTS ONE STUD SPACE FROM FIRST LAYER OF PERIMETER AND 12"O/C ON INTERMEDIATE STUDS. INCHES AT t PCF DENSITY. POLYISOCYANURnTE FOnM INSULATION HAS BEEN <br /> GREEN BOARD)MOUNT TO FIRST LAYER OF GYPSUM BOARD W/�i8 (OFFSET VERTICAL JOINTS ONE STUD SPACE) TESTED TO A MAXIMUM THICKNESS OF 3 INCHES AT 1.9 PCF AND HAS A FLAME <br /> X 2"DRYWALL SCREWS(PM 853-13379)9"O/C AROUND SPREAD OF 25 AND A SMOKE PRODUCT OF 395. 1096 W.DECATUR STREET <br /> PERIMETER AND 12"O/C ON INTERMEDIATE STUDS AND 24"O/C ON EQUIPMENT ROOM SIDE 3. INTERIOR PANELING IS LISTED 70 HAVE A FIAMESPREAO OF 200 OR LESS. DECATUR,IL 62522 <br /> TOP&BOTTOM RUNNERS. SECOND LAYER OF GYPSUM BOARD:5/8"TYPE X 4. THIS ENCLOSURE IS CLASSIFIED AS USE GROUP U,TYPE 56 CONSTRUCTION; <br /> 3 5/8"-NO.25 C.S.GALV.CHANNEL SHAPE"C"STUD GYPSUM BOARD;VERTICALLY ORIENT&MOUNT TO 5. DESIGN CR�TERIA <br /> (MIN);1 B"O/C;SCREWED TO UPPER&LOWER TRACK FIRST LAYER OF GYPSUM BOARD W/#6 X 21/4" WIND LOAD=125 MPH FLOOR DEAD LOAD=35 PSF DRAWN BY: PP <br /> W/1/2"PHILLIPS PAN HEAD SELF TAPPING SCREWS DRYWALL SCREWS(P/N 853-00113)9"O/C AROUND ROOP LIVE LoaD=�oo PSF WALL DEAD LOAD=35 PSF <br /> (P/N 85311535)(SCREW AT 4 PLACES) PERIMETER AND 12"O/C ON INTERMEDIATE STUDS FLOOR LIVE LOAD=�35 PSF SNOW LOAD=8o PSF CHECNED BY: TAZ <br /> STAGGER SEAMS,TAPE AND FLOAT JOINTS; AND 24"O/C ON TOP&BOTTOM RUNNERS.(OFFSET ROOF DEnD LOAD=a5 PSF SEISMIC DCPOSURE GROUP=tll <br /> THEN PAINT TO MATCH CONCRETE WALLS � VERTICAL JOINTS ONE STUD SPACE FROM FIRST 6. F�=5000 PSI(a)28 DAYS(EQUIPMEN7 ENCLOSURE) DATE: OB/22/15 <br /> LAYER OF GYPSUM BOARD) <br /> � 7. ENCLOSURE AND ASSOCIATED EQUIPMENT IS PROVIDED BY OWNER UNDER PROJECT#. 331913 <br /> FIRE BARRIER SEALANT TOP,BOTTOM AN DBOTH VERTICAL � 20 GAGE-3 5/8"UPPER&LOWER TRACK SEPARA7E CONTRACT.E�UIPMENT ENCLOSURE INFORMATION INDICATED <br /> JOINTS ON BOTH SIDES OF THE PARTITION WALL � 1/4"0 X 2"TAPCONS(a�16"O.C. HEREIN IS PROVIDED FOR REFERENCE ONLY AND IS TAKEN FROM sr�e77rr� <br /> Z � VENTILATION NOTES' NUINUFACTURER'S AVAILABLE DATA. REFER TO CIVIL,STRUCTURAL AND EQUIPMENT <br /> � " ELECTRICAL DRAWINGS FOR WORK TO BE PERFORMED UNDER THIS CONTRACT. ENCLOSURE <br /> TWO-HOUR RATED PARTITION `� � 1. AIR CONDITIONING IS PROVIDED BY A BARD WALL g. pRIOR TO PROJECT CLOSE OUT AND SHELTER INSTALLATION,THE GENERAL PLAN&SECTION <br /> (DETAIL PROVIDED BY SHELTER MOUNTED SELF-CONTAINED ENERGY EFFICIENT CONTRACTOR IS TO CLEAN THE SHELTER FLOOR AND APPLY A STATIC-FREE <br /> MANUFACTURES,2-HOUR RATED WALL SECTION"A" COOLING SYSTEM,MODEL#WA602-AOSEX2XI,5 TON, y�l(V(TO THE FLOORS. SHEEi NUMBER <br /> PER IBC TABLE 720.1(2)) 3 N.T.S. 120/240 VOLT, 30 AMP,SINGLE PHASE,57,500 BTUH <br /> COOLINC�CAPACIN,10.20 SEER,24"DIA.FAN,2600 CFM 9. LESSEE SHELTER IS NOT FOR HUMAN HABITATION AND HAS AN OCCUPANT LOAD <br /> � WITH FILTER pF p' B�� <br /> 2.ELECTRIC HEAT IS PROVIDED BY 5 KW,18,840 BTUH, <br /> 240 VOLT,SINGLE PHASE HEAT STRIP,WITHIN BARD 10.FIRE SUPPRESSION OF LESSEE SHELTER IS"NONE". <br /> UNIT LISTED ABOVE. USE KIDDE PRO 10 TCM PER 2012 INTERNAT�ONAL FIRE CODE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.