My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2002-44 AMENDING CITY CODE - CHAPTER 68 - MECHANICAL CODE
COD
>
City Clerk
>
ORDINANCES
>
2002
>
2002-44 AMENDING CITY CODE - CHAPTER 68 - MECHANICAL CODE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2016 11:52:27 AM
Creation date
3/1/2016 11:52:26 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2002-44
Res Ord Title
AMENDING CITY CODE - CHAPTER 68 - MECHANICAL CODE
Approved Date
6/3/2002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. DELETIONS. The following numbered articles or sections <br /> of said Code are deleted therefrom and the provisions thereof are not adopted <br /> hereby: <br /> International Mechanical Code Section No. (inclusive) <br /> 103.1 - 103.2 <br /> 106.5.2 - 106.5.3 <br /> 108.4 <br /> 109 <br /> 304.9 ', <br /> International Fuel Gas Code Section No. (inclusive) <br /> 103.2 <br /> 106.5.2 <br /> 108.5 <br /> 109 (IFGC) <br /> 7. AMENDMENTS. <br /> (c) Reference to ICC International Plumbing Code in <br /> Chapter 16 changed to reference Illinois State Plumbing Code, 1998 as <br /> amended. <br /> (d) M-304.9 Guards. Guards shall be provided where <br /> appliances, equipment, fans or other components that require service are <br /> located within 10 feet of a roof edge or open side of a walking surface and such <br /> edge or open side is located more than 6 feet above the floor, roof or grade <br /> below. The guard shall extend not less than 30 inches beyond each end of such <br /> appliance, equipment, fan or component and the top of the guard shall be <br /> located not less than 42 inches above the elevated surface adjacent to the guard. <br /> The guard shall be constructed so as to prevent the passage of a 21 inch <br /> diameter sphere and shall comply with the loading requirements for guards <br /> specified in the International Building Code. <br /> Exception: HVAC equipment located on a roof with the <br /> service side of the unit located 10 feet or more from the roof edge guards are <br /> not required, provided the distance from any side of unit is not less than 6 feet <br /> from the roof edge. <br />
The URL can be used to link to this page
Your browser does not support the video tag.