My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2002-16 AMENDING CITY CODE - CHAPTER 69 - ELECTRICAL CODE
COD
>
City Clerk
>
ORDINANCES
>
2002
>
2002-16 AMENDING CITY CODE - CHAPTER 69 - ELECTRICAL CODE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2016 2:53:33 PM
Creation date
3/1/2016 2:53:33 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2002-16
Res Ord Title
AMENDING CITY CODE - CHAPTER 69 - ELECTRICAL CODE
Approved Date
4/1/2002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�1) N.E.C. 230-2 Number of Services - onlv one service <br /> drop or lateral shall be permitted unless written a�proval bv the Inspection <br /> Division is obtained for the conditions (al through�dl of said Article 230-2. <br /> �21 N.E.C. 230-43 Service - entrance conductors shall be <br /> installed in accordance with the applicable recLuirements of this code coverin� <br /> the txpe of wiringLmethod used and shall be limited to the followin�methods: <br /> �al Rigid metal conduit: <br /> �bl Intermediate metal conduit; <br /> ,�cl RiQid nonmetal conduit. <br /> Anv other method described shall have written consent of the Inspection <br /> Division and local utili company. <br /> �31 N.E.C. 230-70 (al Location. The service <br /> disconnectin� means shall be installed at a readilv accessible location either <br /> outside of a building or structure, or inside nearest the point of entrance of the <br /> service conductors.but not to exceed ten feet. <br /> �41 Where citv water is available, the electrical service <br /> shall be grounded to the cold water �ning with a jumper around the water <br /> meter. <br /> 10. CODE APPLICATIONS - SPECIFIC. <br /> A. New buildings of all types: <br /> `1� _ i nnn _a:a:__ _r�L_ ,.T..4:,._.., �,....�.:�_, r_a_ The 2002 <br /> l <br /> edition of the National Fire Protection Association will be the accepted code <br /> for all electrical wiring installations, ' <br /> « „ <br /> « <br /> , � <br /> ���e�eee�ten ." provided that Article 210.52 (Cl(21 and (31 shall be <br /> o t� ional. <br /> (3) Whenever a new service is installed, the electric meter shall <br /> be located on the outside of the building unless written approval from�g <br /> �er the local utili companv and the City Building Inspections Division is <br /> obtained. <br />