98-77 AMENDING THE CITY CODE - CHAPTER 67.1
COD
>
City Clerk
>
ORDINANCES
>
1998
>
98-77 AMENDING THE CITY CODE - CHAPTER 67.1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2016 10:50:46 AM
Creation date
3/15/2016 10:50:44 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
98-77
Res Ord Title
AMENDING THE CITY CODE - CHAPTER 67.1 - FLOOD PLAINS
Approved Date
12/7/1998
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(e) the finished interior grade shall not be less than the finished exterior grade; <br /> (fl all structural components below the flood protection elevation shall be <br />, constructed of materials resistant to flood damage; <br /> . (g) water and sewer pipes, electrical and telephone lines, submersible pumps, <br /> and other service facilities may be located below the flood protection elevation provided they are <br /> waterproofed; and, <br /> (h) the area below the flood protection elevation shall be used solely for parking <br /> or building access and not occupied as habitable space. <br /> C. Manufactured homes, or travel trailers to be installed on site for more than 180 days, <br /> shall be: <br /> i. elevated to or above the flood protection elevation; and, <br /> ii. shall be anchored to resist flotation, collapse, or lateral movement by being <br /> tied down in accordance with the Rules and Regulations for the Illinois Mobile Home Tie-Down <br /> Act issued pursuant to 77 IL Adm. Code 870. <br /> D. Non-residential buildings may be structurally dry floodproofed (in lieu of elevation) <br /> provided a registered civil engineer certifies that: <br /> i. below the flood protection elevation the structure and attendant utility facilities <br /> are watertight and capable of resisting the effects of the base flood; <br /> ii. the building design accounts for flood velocities, duration, rate of rise, <br /> hydrostatic and hydrodynamic forces, the effects of buoyancy, and the impact from debris and <br /> ice; and, <br /> iii. flood proofing measures will be incorporated into the building design and <br /> operable without human intervention and without an outside source of electricity. <br />