My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-14 GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
COD
>
City Clerk
>
ORDINANCES
>
2016
>
2016-14 GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2018 8:42:46 AM
Creation date
3/23/2016 4:19:54 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2016-14
Res Ord Title
GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
Approved Date
3/21/2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�— c . =F� � _ � s <br /> ����_x �'-3_�_ sr�-���a .�"3�z <br /> U <br /> KEY � <br /> O(3)#3/0 8(1)#2 GND IN 2-1/2"C � � <br /> (4)#12&(1)#12 GND IN 1"C NOTE: � <br /> OO (SEE NOTE) E.C.TO PROVIDE(2)20A p <br /> 1-POLE CIRCUIT BREAKERS ►- <br /> FOR BATTERY CHARGER <br /> (2)CAT-5 BELDEN IN 1"C W <br /> OFROM GENERATOR TO ALARM AND JACKET HEATER � a <br /> BOX.LEAVE 25'SPOOLED IN � � <br /> ALARM BOX <br /> O4 (2)#12 THWN IN 3/4"C � <br /> O5 (2)#16 THWN.LEAVE 25'OF � W <br /> #16 IN ALARM BOX V <br /> 0 <br /> � <br /> u <br /> � <br /> (2)#12 THHN/THWN FROM GENERATOR TO Q s o <br /> TRANSFER SWITCH PER GENERAC REQUIREMENTS. �s"o� <br /> TRANSFER SWITCH �t�d� <br /> GENERATOR UTILITY SERVICE 120/240V F W��� <br /> #1 6 T H W N 1 P H A S E 3 W I R E �vJ o u P� <br /> �NKra <br /> #2GROUND — Wzm Y�m <br /> TAG CONDUCTORS L O KWH METER �0 o a=� <br /> GENERATOR "REMOTE START' 120/240V 3 WIRE — U��a LL <br /> G 3/4"x 10' <br /> REMOTE START 2#16 THHN STRANDED FROM GENERATOR = ' �i <br /> WIRING WIRING BLOCK. GROUND ROD <br /> - - - - - - - - - - � �� <br /> SEE NOTES#1 AND#2 � BATTERY �� <br /> IF NOT PRESENTLY ON SITE E.C.MUST TRANSFER SWITCH PROPOSED FOUR-PLEX CHARGE& <br /> PROVIDE: GENERATOR POWER FAIL GFI RECEPTACLE(NEMA BLK HTR. I <br /> THE A.C.FAIL RELAY IS CONNECTED TO TAG CONDUCTORS 3R)TO BE MOUNTED I <br /> EACH PHASE OF THE INCOMING POWER. GENERATOR WITHIN HOUSING OF � a F g <br /> THE NORMALLY OPEN CONTACTS CLOSE 3 POWER FAIL GENERATOR(FOR COLD � m a f � � 3 m <br /> UPON LOSS OF POWER SENDING AN ALARM. WEATHER HEATERS) N <br /> m <br /> GENERATOR I � a ' ' � ' � <br /> v o � o o � o <br /> FUEL TANK RUPTURE TAG CONDUCTORS 1 �o 0 0 <br /> IF INNER HULL LEAKS FUEL TANK W <br /> THE ALARM CONTACTS RUPTURE I j 4 5 <br /> WILL OPEN SENDING � a o <br /> AN ALARM GENERATOR 3 I N Z w � i o g <br /> � <br /> LOW FUEL 2 o j � rc $ w rc o m <br /> IF FUEL IS LOW THE TAG CONDUCTORS I w w o w rc o z <br /> CONTACTS OPEN SENDING L O W F U E L I w � o j � � j � � <br /> � � <br /> AN ALARM U `� a o y �u <br /> GENERATOR I� > > - o <br /> 4 Iw N � <br /> � <br /> GENERATOR RUN <br /> TAG CONDUCTORS I <br /> GENERATOR RUN <br /> � <br /> GENERATOR � — - - - - - - - - - - � <br /> _ — — _ — _ _ _ — _ — Z v <br /> COMMON TAG CONDUCTORS I I I L-00-1154 <br /> COMMON I NEW 200A ILC W/ATS � <br /> I I HWY 36 & 105 <br /> I I <br /> I � I 2105 E ELDORADO ST <br /> DECATUR,IL 62521 <br /> NOTES: I 5 � � I <br /> � � ORAWNBV BTE <br /> 1)E.0 TO PULL A#16 AWG SOLID RED AND A I I CHECKED BV TnZ <br /> #16 AWG SOLID BLACK FROM THE TRANSFER I ( <br /> SWITCH TO ALARM WIRING BLOCK FOR DATE 07/30/15 <br /> REMOTE START. I 12"x12"x6" I <br /> ALARM BOX PROJECTft 50.170 <br /> 2)E.C.TO PULL ALL ALARM LEADS TO � — — — — — — — — — — — — — — — — — — — — — — — — — � SHEET TITLE <br /> EXISTING ALARM WIRING BLOCK LEAVE A <br /> MINIMUM OF 24"PIGTAILS AT ALARM WIRING GENERATOR SINGLE <br /> BLOCKANDTAGCONDUCTORSAS INDICATED, LINE DIAGRAM S� <br /> TERMINATIONS ON ALARM POINT WIRING ALARM WIRING <br /> BLOCK BY OTHERS. CONDUCTORS CAN BE <br /> RUN EXPOSED. THEY SHALL BE NEATLY SHEET NUMBER <br /> ALARM WIRING BUNDLED USING NYLON TIES AND <br /> � N.T.S. SUPPORTEDAT2'-0"INTERVALSFORANEAT NEW SINGLE LINE DIAGRAM <br /> INSTALLATION. 2 E 1 � <br /> N.T.S. <br />
The URL can be used to link to this page
Your browser does not support the video tag.