My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
95-15 AMENDING CITY CODE - CHAPTERS 25, 69 AND 70
COD
>
City Clerk
>
ORDINANCES
>
1995
>
95-15 AMENDING CITY CODE - CHAPTERS 25, 69 AND 70
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2016 11:56:27 AM
Creation date
3/24/2016 11:56:25 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
95-15
Res Ord Title
AMENDING CITY CODE - CHAPTERS 25, 69 AND 70
Approved Date
4/3/1995
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � � <br /> (i) Every dwelling unit shall be equipped with at least one approved smoke <br /> detector in an operating condition within 15 feet of every room used for sleeping purposes. The <br /> detector shall be installed on the ceiling and at least 6 inches from any wall, or on a wall located <br /> between 4 and 12 inches from the ceiling measured to the top of the detector. All smoke <br /> detectors shall be approved and listed and shall be installed in accordance with the manufacturer's <br /> instructions. <br /> (ii) Every single family residence shall have at least one approved smoke detector <br /> installed on every story of the dwelling unit, including basements but not including unoccupied <br /> attics. In dwelling units with split levels, a smoke detector installed on the upper level shall <br /> suffce for the adjacent lower level if the lower level is less than one full story below the upper <br /> level; however, if there is an intervening door between the adjacent levels, a smoke detector shall <br /> be installed on each level. <br /> (iii) Every structure which (1) contains more than one dwelling unit, or (2) <br /> contains at least one dwelling unit and is a m�ed-use structure, shall contain at least one <br /> approved smoke detector at the uppermost ceiling of each interior stairwell. The detector shall <br /> be installed on the ceiling, at least 6 inches from the wall, or on a wall located between 4 and 12 <br /> inches from the ceiling, measured to the top of the detector. <br /> 8. PENALTY. That no person, firm or corporation shall erect, construct, alter, extend, <br /> repair, remove, demolish, maintain, operate, use or occupy any structure or equipment regulated <br /> by the provisions of this Chapter or of the Code adopted hereby, or by the rules or directives <br /> promulgated or notices issued thereunder, or cause the same to be done, contrary to or in conflict <br /> with or in violation of any of said provisions, rules, directives or notices, and any person, firm or <br />
The URL can be used to link to this page
Your browser does not support the video tag.