Laserfiche WebLink
, fV. F�roject Location Map and/or Photographs <br /> A project location map shall be included in the application. The project location map should <br /> show the crossing(s) for which application is being made, as well as any other improvements <br /> that are being submitted in conjunction with this application. If project is a part of a "corridor" <br /> project, indicate the limits of the entire "corridor" on the map. Paper size shall not exceed 11 x <br /> 17 inches. If the bridqe will replace a grade crossing, please provide a photograph of the <br /> existing crossiny If the new structure will replace an existinq bridqe, please provide a <br /> photoqraph of the existinc�structure. <br /> V. . Project Summary. <br /> Application to (check all that apply): , <br /> X Reconstruct existing grade separation ❑ Construct a new grade separation <br /> ❑ Close adjacent crossing ❑ Increase vertical clearance at highway underpass <br /> ❑ Other (please specify) _ <br /> IS appliCation for: ❑ Design only ❑ Construction only X Design and construction ' <br /> Is application part of a larger "corridor" project: X Yes ❑ No <br /> Use the space below to provide a narrative of the proposed project. Items to include in this ' <br /> section are extenuating circumstances unique to this crossing, such as heavier seasonal , <br /> traffic, visibility restrictions caused by trees, buildings, etc., proximity of schools and public , <br /> buildings, etc., which explain why this crossing should be funded. Explain any work to by <br /> � done by the local agency, such as roadway improvements in the immediate vicinity of the i <br /> grade separation project. Approximate costs should be listed for each item of work to be � <br /> done. <br /> The purpose of ourpro�'ect is to improve a grade separation located in Decatur, Illinois. <br /> The current underpass, constructed in 1936, does not meet American Disabilities Act <br /> criteria The main Qroblems include the width of sidewalks, the lack of landinqs and <br /> handrails for assistance and need for additional overhead liqhtinq. The sidewalks do <br /> not meet width criteria for bicycle use Additionally, the crossinq is unsafe due to <br /> regular pedestrian usaqe over the railroad tracks. The proiect would ensure ADA <br /> compliance, and safety for pedestrians and bicyclers. <br /> Last year the Decatur Housing Authority was awarded a Hope VI Grant bv HUD in the <br /> amount of $35 million to redevelop the surrounding area, known as the "Near North <br /> Area." <br /> The improvements to this crossing would qreatly benefit the residents of the area and <br /> provide improved safetv conditions. <br /> VI. Evidence of Community Effort and Support <br /> Any preliminary engineering or planning studies, along with cost estimates, that have been <br /> prepared for this project should be included with your application. List any past efforts to <br /> improve safety at railroad crossings within applicant's jurisdiction. If any sfudies have been <br /> done regarding railroad crossing elimination or consolidation, include that information. <br /> Attached please find a coeY of the engineering studkfor this project, completed bv <br /> WVP Corporation. <br />