Laserfiche WebLink
, . . 1 . ' . <br /> ,� . <br /> , , . <br /> k. Boxes or conduits with exces- <br /> sive number of conductors; <br /> 1. Knob and tube wirinq in areas <br /> other than inside walls or at- <br /> tics; <br /> In keepinq with safe electrical in- <br /> stallations, all unsafe conditions <br /> other than specifically noted <br /> above, should be disclosed to the <br /> owner by the electrical contractor <br /> and corrected before inspection. <br /> 11. SERVICE CONNECTIONS. The utility company may connect <br /> the electrical service to the structure when the service is in- <br /> stalled permanently on the structure and upon order of the In- <br /> spection Department. Where services have been damaqed due to <br /> weather conditions, a permit and inspection will be necessary <br /> only when new conductors are beinq installed. Such inspections <br /> will be of the electrical service only. <br /> Durinq severe weather conditions the Superintendent of the <br /> Inspection Department may waive all permits and inspections. Un- <br /> der such conditions the repaired services must remain the same <br /> size and materials must be used accordingly. If a larger size <br /> service is requested by the owner, then all such provisions of <br /> this code shall apply. <br />