� �• r' <br /> . . ♦� <br /> ' � '• <br /> � �, � � a <br /> + � . <br /> toilet, bathroom and kitchen floor surface shall be constructed <br /> and maintained so as to permit such floor to be kept in a clean <br /> and sanitary condition." <br /> (cc) PM 303.8 by deleting the period after the second sen- <br /> tence and insertinq the words "and shall have intermediate rails, <br /> balusters or other construction such that a sphere with a <br /> diameter of 6" cannot pass through any opening." <br /> (dd) PM 403.2 by deleting the Exception noted in this Sub- <br /> section. <br /> (ee) Add a subsection PM 403 . 5 . 1 as follows : <br /> PM 403.5. 1 - Dwellinq Units: Every dwelling unit shall contain <br /> a minimum gross floor area of not less than 150 square feet for <br /> the first occupant, and 100 sq. ft. for each additional occupant. <br /> The floor area shall be calculated on the basis of the total area <br /> of all habitable rooms. <br /> (ff) PM 403. 6 by insertinq after the first sentence thereof <br /> the words "An efficiency apartment may be allowed if the total <br /> area equals that required for the total of a living room, dining <br /> room, kitchen, and bedroom as set farth in Table PM-403 . 5, if <br /> the total square footaqe is equal to or greater than that re- <br /> quired in PM 403 . 3 and the ventilation is equal to or greater <br /> than the total required in PM 402 . 1." <br /> (gg) Add a subsection PM 403 . 11 as follows: Below Grade <br /> Rooms: Rooms partially or completely below grade shall not be <br /> used as habitable space unless: <br /> 1. Floors and walls are water-tight so as to prevent entry <br /> of moisture. <br />