Laserfiche WebLink
Section 6. That Section 5 of Chapter 75 of the City Code of the City of Decatur be, and <br /> the same is hereby, amended and modified so that said Section 5 of Chapter 75 shall provide as <br /> follows: <br /> 5. WATER SERVICE PIPE. Water service pipe from the corporation stop to the <br /> building other than for services larger than two inches in diameter shall be cold drawn, soft <br /> annealed, seamless copper suitable for underground service with proper bending temper with <br /> quality and properties equal to A.S.T.M. Class K specifications. For services of two inches in <br /> diameter or less, from the outlet side of the curb stop to the meter only, polyethylene pipe with <br /> copper tracing wire may also be used that meets all specifications for, and is installed per the <br /> Illinois Plumbing Code and AWWA standards for polyethylene pipe. For services larger than <br /> two inches in diameter materials as are approved in the City of Decatur specifications for water <br /> main installations may be used with the approval of the Public Works Director. Between water <br /> main tap and curb stop there shall be a continuous unspliced run of pipe. <br /> Section 7. That the City Clerk be, and she is hereby, authorized and directed to cause the <br /> provisions hereof to be appropriately set out in the City Code and to cause the same to be <br /> published in pamphlet form according to law. <br /> PRESENTED, PASSED, APPROVED AND RECORDED this CO day of <br /> February, 2017. <br /> .° JULIE MOORE WOMAYOR <br /> ATTEST: <br /> A'IA� `V <br /> CITY CLE C <br /> PUBLISHED this---�day of �.7 , 2017. <br /> ti <br /> CITY CLE <br />