Laserfiche WebLink
LIGHTS ON BARRICADES (BDE) <br /> Effective: January 1, 2018 <br /> Revise Article 701.16 of the Standard Specifications to read: <br /> "701.16 Lights. Lights shall be used on devices as required in the plans, the traffic control <br /> plan, and the following table. <br /> Circumstance Lights Required <br /> Daylight operations None <br /> First two warning signs on each approach <br /> to the work involving a nighttime lane Flashing mono-directional lights <br /> closure and'ROUGH GROOVED <br /> SURFACE"(W8-1107)signs <br /> Devices delineating isolated obstacles, <br /> excavations,or hazards at night Flashing bi-directional lights <br /> (Does not apply to patching) <br /> Devices delineating obstacles, <br /> excavations,or hazards exceeding Steady bum bi-directional lights <br /> 100 ft(30 m)in length at night <br /> (Does not apply to widening) <br /> Channelizing devices for nighttime lane None <br /> closures on two-lane roads <br /> Channelizing devices for nighttime lane None <br /> closures on multi-lane roads <br /> Channelizing devices for nighttime lane <br /> closures on multi-lane roads separating None <br /> opposing directions of traffic <br /> Channelizing devices for nighttime along Steady bum mono-directional lights <br /> lane shifts on multilane roads <br /> Channelizing devices for night time along Steady bum bi-directional lights <br /> lane shifts on two lane roads <br /> Devices in nighttime lane closure tapers Steady bum bi-directional lights <br /> on Standards 701316 and 701321 <br /> Devices in nighttime lane closure tapers Steady bum mono-directional lights <br /> Devices delineating a widening trench None <br /> Devices delineating patches at night on None <br /> roadways with an ADT less than 25,000 <br /> Devices delineating patches at night on None <br /> roadways with an ADT of 25,000 or more <br /> Batteries for the lights shall be replaced on a group basis at such times as may be specified <br /> by the Engineer." <br /> Delete the fourth sentence of the first paragraph of Article 701.17(c)(2) of the Standard <br /> Specifications. <br /> Revise the first paragraph of Article 603.07 of the Standard Specifications to read: <br />