My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-67 Ordinance Amending City Code Chapter 69 Electrical Code
COD
>
City Clerk
>
ORDINANCES
>
2018
>
2018-67 Ordinance Amending City Code Chapter 69 Electrical Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2018 1:47:48 PM
Creation date
11/6/2018 1:47:46 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2018-67
Res Ord Title
2018-67 Ordinance Amending City Code Chapter 69 Electrical Code
Department
Econ and Com Dev
Approved Date
11/5/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chapter 69 <br /> (3) N.E.C. 230.70 (a) Location. The service disconnecting means shall be installed at a <br /> readily accessible location either outside of a building or structure, or inside nearest point of <br /> entrance of the service conductors, but not to exceed ten feet. <br /> (Amended, Ordinance No. 2005-81, September 6, 2005) <br /> (4) Where city water is available, the electrical service shall be bonded to the cold water <br /> piping with a jumper around the water meter. <br /> (Amended, Ordinance No. 2005-81, September 6, 2005) <br /> (Amended, Ordinance No. 2002-16, April 1, 2002) <br /> (Amended, Ordinance No. 2000-96, November 6, 2000) <br /> (5) Sizing of service entrance conductors shall be one of the following: (a) to main <br /> breaker with no reduction of ampere rating; (b) to approved calculated load where multiple <br /> disconnects are used, with no reduction of ampere rating; (c) to rated buss of equipment when no <br /> calculated load is provided with no reduction of ampere rating. <br /> (Amended, Ordinance No. 2008-09, March 17, 2008) <br /> (Amended, Ordinance No. 2005-81, September 6, 2005) <br /> (Amended, Ordinance No. 2002-42, May 20, 2002) <br /> (6) PVC risers up utility poles shall be Schedule 80. <br /> (Amended, Ordinance No. 2008-09, March 17, 2008) <br /> (7) Metal elbows and conduits at utility poles and building service shall be connected to <br /> an effective grounding path, by the electrical contractor and installed as per N.E.C. 250.80. <br /> (Amended, Ordinance No. 2008-09, March 17, 2008) <br /> 10. CODE APPLICATIONS - SPECIFIC. <br /> A. New buildings of all types: <br /> 1) The 2014 edition of the National Fire Protection Association will be the accepted <br /> code for all electrical wiring installations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.