ASCOM <br /> Exhibit A-3 <br /> AECOM 312 938 0300 tel <br /> 303 East Wacker Drive 312 373 6800 fax <br /> Suite 1400 <br /> Chicago,IL 60601 <br /> www.aecom.com <br /> documented with digital photographs of each manhole, including location of defects. AECOM owns a <br /> pole/down-hole camera to better view defects observed without the need to enter the manhole. <br /> Recommendations will be made for replacement, rehabilitation, or repair. As part of the inspection, <br /> the structure location, construction type, structural condition, frame, chimney, cone, barrel, bench, <br /> and step condition will be noted. <br /> Inspection data will be entered into a database, spreadsheet or on a manhole inspection form <br /> modified to include criteria important to the City. Manhole inspections primarily identify structural <br /> conditions and defects. As part of the inspections, the following items will be recorded: <br /> • Manhole number <br /> • Street location <br /> • Date of inspection <br /> • Name of inspector <br /> • Cover type <br /> • Frame grade, condition, and seal <br /> • Presence and condition of internal boot <br /> • Step condition <br /> • Chimney type and condition <br /> • Cone type and condition <br /> • Barrel type and condition <br /> • Bench condition (if applicable) <br /> • Sketch showing pipes entering and exiting each manhole <br /> • Pipe sizes and material for all pipes entering or exiting each manhole <br /> • Depth of pipe inverts, as measured from the structure rim <br /> • Underdrain pipes entering each manhole <br /> • Condition/seal of underdrain pipes <br /> At a minimum and with City approval, photographs will be taken as follows: <br /> • With the cover on, showing pavement/ground surface around the manhole and in the vicinity <br /> of the manhole. <br /> • With the cover opened, showing a view of the chimney and the chimney/frame interface <br /> • From the top of the manhole looking down. <br /> • All significant defects. <br /> Pipe orientation shown on the base map will be verified by the inspection crew for all manholes. A <br /> sketch will be completed showing the orientation/direction of all pipes entering or exiting the manhole <br /> along with pipe sizes and pipe material. No confined space entry into the existing manholes will be <br /> performed. <br /> The final report will document system defects, including the results of the structure inspections, <br /> including observed conditions, and prioritized rehabilitation. Recommendations for future work, based <br /> on the results of the structure inspections, will be included in the final analysis. <br /> This task will assist us in our study evaluation in confirming connectivity of inlets and catch basins to <br /> the existing sewer system. <br /> Deliverables: <br /> • Structure Inspection Results and Review(included in Task 5) <br /> 3 <br />