Laserfiche WebLink
ADDENDUM NUMBER 03 <br /> All prospective Bidders for the City of Decatur, Illinois, Clarifier Conversion Project No. 2016-03 <br /> are directed to the following additions and/or modifications to the original advertised "Project <br /> Manual, Specifications and Construction Plans". These documents are dated October 2021. <br /> This addendum forms a part of the bidding and contract documents and requires <br /> acknowledgement by the Bidder of receipt in the space provided on Page 16 of the Project <br /> Manual Bid Proposal. <br /> SPEC. SECTION <br /> ITEM and/or PLAN SHEET(s) DESCRIPTION <br /> Section 11215 — Horizontal REPLACE last sentence of 2.01 B 2. with "The need for <br /> 1 Self-Priming Rotodynamic a suction check valve or external priming 'deViGe shall <br /> Pump—General, Page 4 not be permitted." <br /> Section 11215-01 — REPLACE 2.02 C 2. in its entirety with "Pump Reprime <br /> 2 Horizontal Self-Priming Lift: At the specified speed and impeller diameter <br /> Rotodynamic Pump— utilizing the external priming assist device shown on the <br /> Dewatering, Page 2 Drawings, as needed." <br /> Alum skid pump supplier shall provide the local pump <br /> control panel as specified, but a separate PLC is not <br /> Section 11241 — Liquid required. When in Auto mode the SCADA system shall <br /> 3 Chemical Feed System fully control the pumps. If the SCADA system is out of <br /> Clarification service or being upgraded, the local system control will <br /> be available to locally control the pumps. An hour <br /> counter in lieu of a rotation counter is acceptable. <br /> Section 16903 —Control REPLACE last sentence of 1.01 A. in its entirety with <br /> 4 Panels Page 1 "Development of HMI application will be by B& <br /> Concentric Integration." <br /> REPLACE Paragraph 2.02 B. 6 c. in its entirety with <br /> Section 16903 —Control "Provide Phoenix Contact PT-IQ for 4-20ma Analog 1/0 <br /> 5 Panels signals and Phoenix Contact PT-2X1 VA-120AC-ST for <br /> Page 7 120V Discrete 1/0 signals. (Series wire all SPD fail <br /> signals to one discrete input to PLC)" <br /> Section 16905—Systems ADD Item B.6. as follows, "PH (AIT-202) shall monitor <br /> 6 Integration the PH level of the effluent of the Filtered water. The <br /> Page 5 SCADA system shall indicate the PH level of the water." <br /> Section 16905 —Systems ADD Item B.7. as follows, "FIT-023 (16" magnetic meter <br /> 7 Integration for flow). This meter will indicate flow in the wash water <br /> Page 5 return line in gpm or MGD with a local display. The <br /> SCADA will also indicate such flow." <br /> 8 Section 16905 —Systems REVISE Item C.7. to reference P-121 in lieu of P-101 <br /> Integration, Page 6 for the South Claricone Dewatering Pump. <br /> ADD Item C.B. as follows, "FE-101: The flow totalizer <br /> Section 16905 —Systems will indicate the amount of flow from the plant water <br /> 9 Integration system to the South SCC Water Jet Influent. The <br /> Page 6 SCADA system shall indicate the amount of flow of the <br /> associated plant water and totalize." <br /> Decatur WTF/16011-01 1 of 2 Addendum No. 03 <br />