' Crawford,Murphy&Tilly
<br /> William Street Pump Station,E.Main Street&S.29th Street, Decaur, IL
<br /> October 6,2022/IDEAL Number 25115
<br /> ' replacement flooring. Use caution if removing replacement flooring. If old black mastic is found in isolated areas or throughout,
<br /> even if not identified during an inspection, it should be treated as asbestos containing for renovation purposes, or if building
<br /> materials are to be recycled, as it is likely to contain asbestos. If underlying flooring is found which is not identified in the report,
<br /> ' additional inspection is necessary.
<br /> BLACK MASTIC INFORMATION
<br /> When replacement flooring is sampled, multiple colors of mastic may be present below it.When black mastic is found
<br /> amongst the multiple colors, it is likely the original mastic,and it is also likely to contain asbestos. Without inspection of the
<br /> entire floor space, it is impossible to know whether the black mastic is residual or if it is prevalent.
<br /> It is noteworthy that in the 1990's, schools did not typically remove old black mastic when they removed floor tile. Rather,
<br /> they just covered over it. Therefore, it is very common to find prevalent black mastic and a newer mastic(often yellow)
<br /> underneath replacement flooring.
<br /> y In addition,the laboratory may not report the presence of black mastic in replacement flooring samples, or they may report
<br /> it at quantities less than 1%,which meets the definition of a non-asbestos containing material.Therefore,when reviewing
<br /> inspection reports, you may read that a replacement mastic is non-asbestos containing. We recommend using caution
<br /> when replacement flooring is removed, even if sample results say the underlying mastic is non-asbestos containing. If
<br /> ' black mastic is discovered along with other colors of mastic, it should be treated as asbestos containing. The sample
<br /> results may not accurately reflect the entire floor surface.
<br /> For pre-demolition inspections,the inspection was completed under the assumption that all non-regulated asbestos containing
<br /> materials will remain in the building during the demolition process and will be taken to the landfill as general construction debris.
<br /> If present,these materials were sufficiently sampled for this purpose. If building materials are to be recycled, additional
<br /> sampling may be necessary(NOBS, materials with trace amounts of asbestos, etc.). Please note that no materials with black
<br /> mastic attached should be recycled without first removing the black mastic. Black mastic should be treated as asbestos
<br /> containing, regardless of laboratory analysis results for the black mastic.
<br /> If the inspection included the building exterior, it was not an exhaustive inspection of the entire exterior surface area, but,
<br /> rather, random areas were inspected.Additionally,on multi-level buildings, exterior materials may appear homogeneous from
<br /> ' the ground to the top levels, but it is possible that different building materials are present. Care should be taken during
<br /> renovation and/or demolition activities of multi-level buildings to ensure that exterior materials identified are homogeneous.
<br /> Room numbers, room dimensions, occupant names, buildings years, etc. may not be accurate in this report if information
<br /> ' provided to us, such as on a diagram,was not current, and in the future if building information changes after the date of the
<br /> inspection.
<br /> A material may be called"fireproofing" in this report for general description purposes; however, such a description shall not
<br /> ' mean that it is a fire-rated material.
<br /> While inaccessible materials,spaces or areas are excluded from the scope of the inspection, some may have been inspected.
<br /> Photos may not be provided for all materials. Photos either reflect sample locations(when designated with a number)or
<br /> general material locations (when sample number is not included in the photo). When a photo is shown with a zero(i.e. MFA-0),
<br /> it typically means the material is assumed to contain asbestos, and no samples were collected. For an assumed material, if the
<br /> Sample Area ID is noted on a diagram, it often reflects the location of the photo.
<br /> ' Samples are analyzed by a laboratory approved or accredited (as applicable) by the National Voluntary Laboratory
<br /> Accreditation Program (NVLAP)or American Industrial Hygiene Association (AIHA).
<br /> ' The analysis results relate only to the materials sampled and only as found in the locations described in this report.
<br /> For qualitative analysis: If asbestos was detected, a material will be reported as an asbestos containing material, even though
<br /> the asbestos was not quantified. If no asbestos was detected, a material will be reported as a non-asbestos containing material.
<br /> Asbestos content within a homogeneous area may vary.Therefore, random samples of a homogeneous area may indicate an
<br /> asbestos content of less than 1%or no asbestos detected,while other random samples taken from the same material may
<br /> indicate an asbestos content of greater than 1%. IDEAL sampled according to accepted sampling protocol (unless otherwise
<br /> ' noted by limitations in the description of the scope of work)and is not liable if materials are re-sampled and found to contain
<br /> asbestos.
<br /> All asbestos containing friable materials are regulated.The process of renovation/demolition may cause non-friable category I
<br /> or non-friable category II materials to become friable, and therefore regulated.Asbestos containing non-friable category II
<br /> materials are generally reported as regulated, as they are likely to become friable during the process of renovation/demolition.
<br /> Exceptions may exist, such as pliable caulking material.
<br /> Ideal Environmental Engineering,Inc. (309)828-4259 www_Jualenvironmental.com
<br /> Page 116