My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
R2024-244 City Project 2021 01
COD
>
City Clerk
>
RESOLUTIONS
>
2024
>
R2024-244 City Project 2021 01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2024 12:20:44 PM
Creation date
6/19/2024 12:18:51 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
R2024-244
Res Ord Title
R2024-244 Resolution Authorizing the Execution of an Agreement with the Norfolk Southern Railway Company for a Storm Sewer Crossing for the Oakland and Grand Sewer Separation Project, City Project 2021-01
Department
Public Works
Approved Date
6/3/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:6D021El7-6D9E-4088-8758-C4AA671332C5 <br /> PIPE DATA SHEET <br /> CARRIER PIPE CASING PIPE <br /> CONTENTS TO BE HANDLED Stormwater n/a(casing) <br /> MAX.ALLOWABLE OPERATING PRESSURE n/a(gravity) n/a(casing) <br /> NOMINAL SIZE OF PIPE 42" 60" <br /> OUTSIDE DIAMETER 52.5" 61.688" <br /> INSIDE DIAMETER 42" 60" <br /> WALL THICKNESS 5.25" 0.844" <br /> WEIGHT PER FOOT 811 lbs 551.2 lbs <br /> MATERIAL Reinforced Concrete Steel <br /> PROCESS OF MANUFACTURE Precast Spiralweld <br /> SPECIFICATION ASTM C76 ASTM A139 Grade B <br /> GRADE OR CLASS Class III 35,000 psi <br /> (Specified Minimum Yield Strength) <br /> TEST PRESSURE n/a(soil tight) 20 psi <br /> TYPE OF JOINT Bell&Spigot Welded <br /> TYPE OF COATING n/a n/a <br /> DETAILS OF CATHODIC PROTECTION n/a n/a <br /> DETAILS OF SEALS OR PROTECTION AT n/a Rubber <br /> END OF CASING <br /> CHARACTER OF SUBSURFACE MATERIAL Clay Clay <br /> APPROXIMATE GROUND WATER LEVEL 23.5'below grade 23.5'below grade <br /> SOURCE OF INFORMATION soil boring soil boring <br /> ON SUBSURFACE <br /> CONDITIONS <br /> Proposed method of installation (refer to NSCE-8 Specification): <br /> ❑X Bore&Jack <br /> ❑ Jacking <br /> ❑ Tunneling (with Tunnel Liner Plate) <br /> ❑ Directional Bore/Horizontal Direction Drilling — Method A <br /> ❑ Directional Bore/Horizontal Direction Drilling— Method B <br /> ❑ Open Cut—All installations directly under any track must be designed as a bored installation. Open cut <br /> installations will be considered on a case-by-case basis by Norfolk Southern's Division Superintendent at the <br /> time of installation. <br /> ❑ Other—Please Specify: <br />
The URL can be used to link to this page
Your browser does not support the video tag.