Laserfiche WebLink
FRONTLINE <br /> COMMUNICATIONS Decatur Police Department <br /> AOiehknMPiave Nanwbctrif J An Oshkosh CeereauA.,fuskrau Crisis Negotiation Vehicle Proposal <br /> Line voltage electrical system equipment and materials included on the apparatus will be listed <br /> and installed in accordance with the manufacturer's instructions. All products will be used only in <br /> the manner for which they have been listed. <br /> Grounding <br /> Grounding will be in accordance with Section 250-6 "Portable and Vehicle Mounted Generators" <br /> of the NEC. Ungrounded systems will not be used. Only stranded or braided copper conductors <br /> will be used for grounding and bonding. <br /> An equipment grounding means will be provided in accordance with Section 250-91 (Grounding <br /> Conductor Material)of the NEC. <br /> The grounded current carrying conductor(neutral)will be insulated from the equipment grounding <br /> conductors and from the equipment enclosures and other grounded parts. The neutral conductor <br /> will be colored white or gray in accordance with Section 200-6 (Means of Identifying Grounding <br /> Conductors) of the NEC. <br /> In addition to the bonding required for the low voltage return current, each body and driving or <br /> crew compartment enclosure will be bonded to the vehicle frame by a copper conductor. This <br /> conductor will have a minimum amperage rating of 115 percent of the nameplate current rating of <br /> the power source specification label as defined in Section 310-15 (amp capacities)of the NEC. A <br /> single conductor properly sized to meet the low voltage and line voltage requirements will be <br /> permitted to be used. <br /> All power source system mechanical and electrical components will be sized to support the <br /> continuous duty nameplate rating of the power source. <br /> Operation <br /> Instructions that provide the operator with the essential power source operating instructions, <br /> including the power-up and power-down sequence, will be permanently attached to the apparatus <br /> at any point where such operations can take place. <br /> Provisions will be made for quickly and easily placing the power source into operation. The <br /> control will be marked to indicate when it is correctly positioned for power source operation. Any <br /> control device used in the drive train will be equipped with a means to prevent the unintentional <br /> movement of the control device from its set position. <br /> A power source specification label will be permanently attached to the apparatus near the <br /> operator's control station. The label will provide the operator with the following information: <br /> • Rated voltage(s)and type (ac or dc) <br /> • Phase <br /> Bid#253 Page 17 Printed: 5/11/2026 <br />