My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
R2003-125 AUTHORIZING THE EXECUTION OF TASK ORDER NO.3
COD
>
City Clerk
>
RESOLUTIONS
>
2003
>
R2003-125 AUTHORIZING THE EXECUTION OF TASK ORDER NO.3
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2016 8:36:05 AM
Creation date
1/13/2016 8:36:04 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
R2003-125
Res Ord Title
AUTHORIZING THE EXECUTION OF TASK ORDER NO.3 FOR CONTINUING AGREEMENT FOR ENGINEERING SERVICES
Approved Date
9/2/2003
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\ <br /> Automatic shutoff actuators are available to automatically close the tapping valves on the <br /> chlorine ton containers if chlorine gas is detected in the chlorine feed room due to <br /> accidental discharge. <br /> Only actuators manufactured by Halogen Valve Systems, Inc. will be evaluated. The only <br /> modifications necessary to the e�sting chlorine feed system would be piping and tubing <br /> modifications to allow the actuators to be mounted directly on the ton container tapping <br /> valves. All piping and equipment downstream would remain unchanged. <br /> This evaluation will include costs for the automatic actuator systems, including controls, <br /> utilities, and the minor modifications to the piping at the ton containers. Engineer shall <br /> prepare a schematic to show the chlorine piping arrangement at the ton containers and the <br /> new actuators. <br /> New Sodium Hvpochlorite Storage and Feed Svstem <br /> Engineer sha11 perform a cursory evaluation for replacement of the existing chlorine <br /> storage and feed equipment with new sodium hypochlorite storage and feed equipment for <br /> drinking water disinfection. <br /> New sodium hypochlorite system equipment would include bulk storage tanks, transfer <br /> pumps, day tanks, metering pumps, piping, valves and controls. The new equipment sha11 <br /> be sized for storing and feeding a 12.5 percent solution of liquid sodium hypochlorite. On <br /> site generation of sodium hypochlorite, or storage and dilution of higher concentrations of <br /> sodium hypochlorite solution will not be evaluated. <br /> The new sodium hypochlorite system would be housed in a new building. The location for <br /> a new building will not be considered or determined in the evaluation. The cost opinion <br /> for the new building will be determined by multiplying the estimated building size by an <br /> � estimated unit cost per square foot plus an appropriate contingency factor. <br /> The expected impact of feeding sodium hypochlorite as a secondary disinfectant following <br /> primary disinfection with chlorine dioxide as it is currently practiced will be addressed. <br /> The evaluation will include costs for a complete sodium hypochlorite system, new <br /> building, utilities, modifications to the existing chlorine dioxide system, if required, and <br /> demolition of the existing chlorine equipment. The estimated annual chemical costs for <br /> year 2003 for feeding chlorine versus sodium hypochlorite will be compared. Engineer <br /> shall prepare a schematic of the hypochlorite feed system and a layout of the new building. <br /> B. REPORT <br /> Engineer shall prepare a report summarizing the findings of the evaluations. The report � <br /> A-3 <br /> City of Decatur Task Order No.3 <br /> Rev.07-25-03 <br />