My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-14 GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
COD
>
City Clerk
>
ORDINANCES
>
2016
>
2016-14 GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2018 8:42:46 AM
Creation date
3/23/2016 4:19:54 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2016-14
Res Ord Title
GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
Approved Date
3/21/2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
=-`;� �M�.�s�:, t _. �}. <br /> . .��.y��� � C�Y3.4 �dly'ss 3'�a14 <br /> U <br /> TO POwER PRIMARY ELECTRICAL NOTES: NOTES: J <br /> SERVICE 1. LEAN CONCRETE,RED-COLORED TOP,MAY 3. CONDUIT SIZE,TYPE,QUANTITY AND _ <br /> BE USED IN PLACE OF COMPACTED SAND. SEPARATION DIMENSION TO BE VERIFIED = <br /> 1.SUBCONTRACTOR SHALL PROVIDE 600AMP,SINGLE PHASE, WITH LOCAL UTILITY COMPANY � Q_ <br /> UTILITY TR,4NSFORMER 120/240 VAC,60HZ SERVICE FOR SITE 2, BURY CONDUITS 42"BELOW GRADE OR 6" REQUIREMEN7S <br /> 12o/24oV,t0 SERVICE GROUND PER UTILITY BELOW FROST LINE,WHICHEVER IS � <br /> RE�UIREMENTS 2.SUBCONTRACTOR SHALL COORDINATE WITH UTILIN GREATER <br /> COMPANY BEFORE THE START OF CONSTRUCTION, RESTORE SURFACE COARSE � <br /> 2 SETS OF 4-qsoo POWER AND TELEPHONE CONDUIT SHALL BE PROVIDED AND MATERIAL AND BASE COARSE TO � � <br /> KCMiL.IN a^CONDUIT. INSTALLED PER UTILITY REQUIREMENTS. RETURN ORIGINAL MATERIAL TO ORIGINAL CONDITION AFTER Q <br /> TRENCH,COMPACT TO MAXIMUM INSTALLATION OF UTILITIES.GRADE � � <br /> 3.FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT DENSITY IN ACCORDANCE WITH SURFACE TO LEVEL. � <br /> REFER TO DRAWINGS PROVIDED BY PANEL MANUFACTURER. ASTM D1557 TRENCH � <br /> PROVIDE PANDUIT UNDERGROUND � <br /> METER CENTER,600A,240/120V, � HAZARD TAPE(FOIL TYPE) Z <br /> 4.SUBCONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE UNDISTURBED <br /> �0,3w4 POSITIONS2ooa Ea,. EQUIPMENT WITH FAULT CURRENT RATINGS GREATER THAN SOIL 'CAUTION-ELECTRICAL LINE BURIED V <br /> NEMa 3R ENCLOSURE BELOW AT 1'-0"ABOVE SAND FOR THE <br /> r T 7 - � THE AVAILABLE FAULT CURRENT FROM THE POWER UTILITY. <br /> i i i S4UARE D METER PAK�K/� �� ���� ENTIRE LENGTH OF THE CONDUIT RUN <br /> I I I I SHORT CIRCUIT RATING _ � \ // <br /> i i i i 5.SUBCONTRACTOR SHALL VERIFY THAT MAIN BONDING - v /�\� ���\ o <br /> � � � � JUMPER AND GROUNDING ELECTRODE CONDUCTOR IS a �� CA-17 COARSE AGGREGATE � <br /> � � � � � ��/� COMPACTED TO 90%STANDARD <br /> i i i i INSTALLED PROPERLY WHEN PANEL IS SERVICE ENTRANCE � ri <br /> i � � i EQUIPMENT � PROCTOR o`� <br /> M M <br /> I I I I \/\\S\�� L'�J o 0 <br /> i i i i - �\��� \y��� �COMPACTED SAND(SEE NOTE 1) �Z=W,�$ <br /> � M � � M � � /�' � � COMPACTED SAND �W��°�9 <br /> i � C O N D U I T S F O R �°1 j��4� <br /> i � i i BED(SEE NOTE 1) �>>��� <br /> L____ _____L____1__________J ELECTRICAL& mm Y� „ <br /> ANTENNA SHARING p o Q= <br /> 3-#2 AWG&1-q6 <br /> WHERE 12"(MIN) �u$d a� <br /> GRND.IN 1}" CONDUIT APPLICABLE SEPARATION ' � /� <br /> 3 ,�,'d► <br /> 2 POWER ONE LINE DIAGRAM UTILITY TRENCH DETAIL ��{V� <br /> N.T.S. SCALE:N.T.S. <br /> 00 > a r- � <br /> m a � � m <br /> N rp <br /> W � � � � <br /> 0 r O O Q O � <br /> O <br /> PLAN VIEW PROPOSED VERTICAL <br /> o � <br /> SUPPORT UNISTRUT HOFFMAN TELCO CABINET a o <br /> 8'-0" PROVIDED BY CUSTOMER <br /> $�_p�� ( ) u, 3 0 � g <br /> 36"x36"x12"NEMA 3R a o > o � Z � <br /> WEATHERPROOF HINGED vi � rc ° � N a z <br /> BREAKER BOX > <br /> COVER ENCLOSURE w � � w rc o z o <br /> u' (1)100A METER SLOT FOR TOWER OWNER � � � rc � � o � <br /> DISCONNECT SWITCH PANEL CUSTOMER TO PROVIOE 3/4" � o a y a Q <br /> a? � TREATED PLYWOOD � ' a <br /> (1)200A METER SLOT FOR LESSEE y <br /> (2)RECEPTACLES WITH �' 600 B BACKBOARO WITHIN N ' <br /> WEATHERPROOF COVERING � AMP ENCLOSURE <br /> MAIN DEMARC <br /> GENERATOR PLUG � OBOXO <br /> °D (2)200A METER SLOTS FOR o <br /> Z � � H vi v vi <br /> N � FUTURE CARRIERS <br /> 0 <br /> I L-00-1154 <br /> FINISHED GRADE � FINISHED GRADE <br /> � HWY 36 & 105 <br /> � � - - <br /> , <br /> - � <br /> � �� �:... <br /> � •. 3/4"CONDUIT FOR •.. r <br /> Z GROUNDING , f 4"MIN.SCH.40 CONDUIT TO 2105 E ELDORADO ST <br /> � = 1"PVC SCH.40 CONDUIT � TELCO PEDESTAL(STUB 2" DECATUR,IL 62521 <br /> o t • 4"CONDUITS � FOR#6 SOLID COPPER ABOVE GRADE)200L6 TEST <br /> � FROM UTILITY GROUND CONNECTED TO CALIBRATED PULL STRING DRAWN BY: BTE <br /> ' PROVIDER ' PRIMARY GROUND GRID , SHALL BE PROVIDED <br /> WITHIN CONDUIT CHECKEDBY rnz <br /> PROPOSED NOTE: n�oPnEV 386 DAVS A VEAR <br /> ��"2�� CONCRETE PIER DATE 07I30/15 <br /> 1. ALL ELECTRICAL PLUMBING MUST BE VERIFIED PRIOR TO INSTALLATION BY PROJECT# so-�io <br /> Call <br /> CONTRACTOR AND MUST MEET GOVERNING CODES,NO EXCEPTIONS. Bejare SHEETTITLE <br /> You Dig <br /> FRONT 2. 1 36"x 36"x 12"NEMA 3R ENCLOSURE(HOFFMAN A-20R20BHCR OR SIMILAR) REAR SINGLE LINE DIAGRAM <br /> AND DETAILS <br /> ILLINOIS SHEETNUMBER <br /> ONE CALL SYSTEM <br /> CALL JULIE TOLL FREE <br /> 1(800)892-0123 �-� <br /> MULTI-GANG UTILITY H-FRAME DETAILS 48H�VOUDIGORE <br /> � N.T.S <br />
The URL can be used to link to this page
Your browser does not support the video tag.