My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-14 GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
COD
>
City Clerk
>
ORDINANCES
>
2016
>
2016-14 GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2018 8:42:46 AM
Creation date
3/23/2016 4:19:54 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
2016-14
Res Ord Title
GRANTING AUTHORITY TO CONSTRUCT WIRELESS COMMUNICATION FACILITY - 2105 EAST ELDORADO STREET
Approved Date
3/21/2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�._ <br /> _�,��_ �:� <br /> TYPICAL KEYED GROUNDING NOTES O I i � <br /> O� #2 AWG TNND SOLID BARE COPPER CONDUCTOR 42"BELOW GRADE I .. I . � . ' � ' I <br /> (TYPICAL)MINIMUM 24"BENDING RADIUS I � . � . . . �� � ." - <br /> O2 5/8"x 10'COPPER CLAD GROUND ROD � � ' ' � ' ' � � <br /> � � I GROUND FENCE GATE I \ � � <br /> O3 GROUND ALL CORNER POSTS WiTH MECHANICAL PIPE CONNECTORS � � I � � � � TO�GROUND RING � � � . ' . I \ `� � O <br /> I GROUND UTILITY H-FRAME POSTS � u> <br /> PERIPHERAL GROUND RING SHOULD BE INSTALLED 1'-2'INSIDE THE I I � ' � ' - _- AND EQUIPMENT CABINETS � � � <br /> O4 FENCE LINE,THE TOWER GROUND RING SHOULD BE INSTALLED A I __ � a <br /> MINIMUM TWO FEET OFF OF ANY STRUCTURE 4 � �-- . � � <br /> O5/S"0 10'LONG COPPERCLAD GROUND ROD WITH INSPECTION WELL, I -�-T -r __.t -� / 3 \ I � q <br /> TOP OF GROUND ROD MAX 24"BURY,SEE DETAIL SHEET E-5 <br /> ---\ ----' 9 <br /> O INSPECTION WELL#2 II � N _____ ___-- r- <br /> � -----6 � \ tL <br /> -- � H <br /> I <br /> BOND TOWER TO GROUND SYSTEM WITH CADWELD TYPE VS, \� � 0 2.5' S' 10' W <br /> O4 LOCATIONS � j 8 10 i 22'■�a•�iM�s TME fuu scuE V <br /> GATE JUMPERS SEE DETAIL ON SHEET E-5 � I �--- METER GROUNDED TO(2) Fow�ar.arvs¢E on�Eanu� <br /> O8 � i i INDEPENDENT GROUND RODS T�TISATREWCE�SCA�E p <br /> PROVIDE AN EXTERNAL#2 TNNCOATED GROUND LEAD FROM GROUND I 1 j INSPECTION SLEEVE SEE SHEET j � <br /> RWG TO ALL METAL CABINETS ON UTILITY BACKBOARD I I E-5 FOR DETAIL. � � , <br /> Og (TELCO,ELEXTRIC,BREAKER PANELS,METER RACKS,JUNCTION BOXES, � i i o i� <br /> ETC.)SLEEVED IN CONDUIT FROM JUST BELOW GRADE TO SAND CABINETS /� � I u�'�o 0 <br /> USING BURNDY TYPE 2 LONG BARREL LUGS WITH NO-OK OR COPPER � � I ��7 d�� <br /> SHIELD / � � i F W�°D O 1 <br /> ELECTRIC METER AND ELECTRIC SERVICE GROUNDING � � � I ����� <br /> 10 / � GROUND ROD(5/8"x10'LONG I ��H�r�e <br /> COORDINATE ALTERNATE WITH PM � / ,I,� COPPER CLAD SPACED 20'O.C.) i Z o��� <br /> VS� <br /> 11 24"x30"x24"FIBEROPTICHANDHOLE ������ i j �U�n a� <br /> 4"x 12"x 1/4"GROUND BAR INSIDE OF HAND HOLE.G.C.TO DRIVE 10' I <br /> i EXTEND#2 TINNED CU WIRE � i <br /> �Z GROUND ROD 8 CLAMP TO GROUND BAR(SEE DETAII 9,SHEET E-7) j � FROM GROUND RING TO FENCE j �� <br /> i POST,EXOTHERMICALLY WELD <br /> 13 MAINTAIN TWO FOOT DISTANCE OFF OF STRUCTURES. \ � j �'� <br /> I � <br /> 14 PLATFORM CORNER POST,STEEL COLUMN,STEEL BEAM&CANOPY GROUND �` � j <br /> I � <br /> 15 CABINET GROUND BOLTED TO UNIT HOUSING \ � I � � I m a � � m � m <br /> I I <br /> 76 VZW DISCONNECTAND ELECTRIC SERVICE GROUND TO GROUND ROD �� � ��,�_ � � ' ' ' ' m <br /> GROUND CHAIN LINK FENCE(TYPICAL)EXOTHERMIC CONNECTION � /� `� pp � a � o e� Q a � <br /> 17 (TYPE VS)GROUND FENCE POSTS WITHIN 6 FEET OF PLATFORM AND 25 �\ j , � �� � � I � ^o ' o � <br /> F E E T o F T O W E R. � �` � � � 2 6 � #2 A W G B C W S O L I D T I N N E D <br /> i i i (UNO)(GROUND RING) <br /> 18 GROUND COAXIAL ANTENNA CABLES TO GROUND BAR BY ANTENNA �� -�� � � <br /> CONTRACTOR TERMINATE CABLES 1'-0"FROM PLATFORM AND INSTALL �` � � ��` 2� 15 � � _Y � o � <br /> LIGHTNING SURGE ARRESTORS ON EACH CABLE GROUND. ��` i ` •� i �� � ---7-�-�-�� � ��\ � o <br /> EXOTHERMICALLY WELD COPPER GROUND BAR TAIL TO HALO GROUND MONOPOLE � �� � � �� 27 ��� � Z Z w � z u g <br /> 19 RING(EXOTHERMIC CONNECTION TYPE TA)BY ANTENNA CONTRACTOR. FOUNDATION �\��-�` \ 24 --+ O F w � � � ~z Z <br /> FINAL CONNECTION BY ELECTRICAL CONTRACTOR. ��` 23 � ��` z, � 14 � � � � W � p Q <br /> 4'7C20'7(1/4"TNND INSULATED COPPER GROUND BA,NON ISOLATED WITH `� i' � y LL m � LL o � <br /> PROPOSED TOWER � w o LL '� o F <br /> ZD 1 0.0'L O N G#2 A W G T N N D S O L I D C O P P E R W I R E W E L D E D T A I L S � �� � -� 13 e � � �u � p � <br /> (HARGER GBIT 14420VVV) GROUND RING � �\ � a Q N Q <br /> 21 GROUND CABLE WAVEGUIDE BRIDGE(TYP.)BY ELECTRICAL CONTRACTOR. �� \�� Z�\� � '� � a <br /> CADWELD TO TOWER BASE � �� / � y a <br /> 4"x20'k1/4"TNND INSULATED COPPER GROUND BAR,NON-ISOLATED,WITH PLATE(TYP.3 PLACES) �`� 18 � � -� `� � <br /> ZZ 10.0'LONG#2 AWG TNND SOLID COPPER WIRE WELDED TAILS \�. 19 �� � -I <br /> (HARGER GBIT 14420VN� NEW ICE �� �y ��� <br /> �� \ 1 { 1 <br /> 23 BOND TOWER GROUND RING TO PROPOSED PLATFORM GROUND RING BRIDGE �`\ �_25 __ <br /> WITH#2 AWG TNND SOLID COPPER CONDUCTOR IN 2 LOCATIONS. _� ' <br /> \�� ____ Z v <br /> TWO#2 LEADS FROM THE EGR TO THE GROUND BAR AT UTILITY FRAME �------ ---- \ ' � � <br /> 24 ON PLATDFORM�TFORM STEEL.CADWELD AT EGR AND DOUBLE HOLE LUGS � �� ��j 2 <br /> I L-00-1154 <br /> 25 BOND RAYCAP TO MGB. 5 <br /> HWY 36 & 105 <br /> EXTEND GROUND CONDUCTORS IN 1/2"RIGID H.W.CONDUIT ADJACENT <br /> 26 TO PAD,OFFSET AND ATTACH TO EXTERIOR OF GENERATOR HOUSING <br /> AND EXTEND TO GROUND LUGS AS REQUIRED,VERIFY LOCATION WITH <br /> GENERaC. 2105 E ELDORADO ST <br /> z7 MGB MOUNTED UNDER PERIMETER BEAM DECATUR,IL 62521 <br /> 28 EXISTING TOWER OR COMPOUND GROUND RING(V.I.F.) / DRAWN BV: BTE <br /> EACH TOWER FOUNDATION TO HAVE AT LEAST ONE ANCHOR BOLT � / CHECKED BV 7aZ <br /> 29 BONDED TO TOWER GROUND RING WITH#2 TINNED SOLID COPPER \\ DATE: 07/30/75 <br /> CONDUCTOR � <br /> OPERATES24HOURS \ / <br /> A DAV 365 DAVS A VEAR \ <br /> � PROJECT# 50.170 <br /> \ <br /> � <br /> SHEET TITLE <br /> LEGEND: aefo,-e \�� GROUNDING DETAILS <br /> [_� GROUND BAR OR ARRESTOR BAR _.`.�i <br /> SPARE GROUND LEAD Y�� \ � <br /> � 5/8"Pl x 10'-0"GROUND ROD � MECHANICAL CONNECTIO SHEET NUMBER <br /> O GROUND SYSTEM TEST WELL --- EXISTING GROUNDING i��wo�s E-� <br /> ONE CALL SYSTEM NOTE: <br /> • CADWELD ORAPPROVED CONNECTION ---NEW GROUNDING �L��J��892-01Z7REE � SITE GROUNDING PLAN SEE GROUNDING DETAILS <br /> 48HWRSBEFORE SCALE 1"=5� ON SHEETS E-5&E-6 <br /> rou�ic <br />
The URL can be used to link to this page
Your browser does not support the video tag.