Chapter 70 <br /> not more that 44 inches above the floor. <br /> 4 . The minimum net clear opening for below-grade room <br /> windows to be used for egress or rescue shall be 5 square feet. <br /> 5 . Means of egress and emergency escape are provided in <br /> accordance with this code. <br /> (cc) PM 604 . 2 by deleting the words "NFiPA 70 listed in <br /> Appendix A" and inserting the words "the National Electric Code <br /> (NEC) , as adopted by the City of Decatur. " <br /> (dd) PM 605. 1 by deleting the period after the word <br /> "manner" and inserting "as per the National Electric Code, as <br /> adopted by the City of Decatur. " <br /> (ee) Add a subsection PM 702 .9. 1 as follows: <br /> PM 702 . 9 . 1 - Stairs and porches: Every stair, porch, fire <br /> escape, balcony, and all appurtenances attached thereto shall be <br /> constructed so as to be safe to use and capable of supporting the <br /> anticipated loads and shall be maintained in sound condition and <br /> good repair, free of deterioration. The maximum riser height for <br /> steps shall be 9" and the minimum tread depth shall be 8" with <br /> variation not exceeding 3/4" in the depth of adjacent treads or <br /> in the height of adjacent risers. " <br /> (ff) PM 705. 5 by substituting the following for this <br /> subsection: <br /> SMOKE DETECTORS <br /> (i) Every dwelling unit shall be equipped with at least one <br /> approved smoke detector in an operating condition within 15 feet <br />