Laserfiche WebLink
. � <br /> Chapter 69 <br /> walls or ceilings (including suspended ceilings) to be opened up, <br /> all wiring, boxes, conduit, etc. exposed by this work shall be <br /> brought up to current code standards. <br /> (2) Buildings or part of buildings used as human <br /> dwellings: <br /> (a) Whenever a new service is installed, the <br /> electrical meter shall be located on the outside of the building <br /> unless written approval from Illinois Power and the City <br /> Electrical Inspection Division is obtained. <br /> (b) Whenever a new electrical service or wiring <br /> of new building additions or rewiring with three (3) or more <br /> additional circuits, the following shall also apply: <br /> 1. Service: The size and usage of appliance <br /> and equipment shall be used as the basis for determining the need <br /> for additional facilities in accordance with the latest adopted <br /> addition of this Electrical Code. <br /> 2 . �eceptacles: Every habitable space in a <br /> dwelling shall contain at least two separate and remote <br /> receptacle outlets. Every laundry area shall contain at least one <br /> grounded type receptacle. Every bathroom shall contain at least <br /> one duplex wall receptacle and be protected by a GFCI. Any new <br /> receptacle must be of the grounded type and installed as per the <br /> NEC. Existing 3-wire grounded type receptacles, wired to a <br /> 2-wire system, shall either be grounded as per the NEC, protected <br /> by a GFCI, or replaced by a 2-wire receptacle. <br />