My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5575 ADOPTING THE ILLINOIS STATE PLUMBING CODE AND ESTABLISHING MINIMUM STANDARDS FOR CERTAIN INSTALLATIONS
COD
>
City Clerk
>
ORDINANCES
>
1971
>
5575 ADOPTING THE ILLINOIS STATE PLUMBING CODE AND ESTABLISHING MINIMUM STANDARDS FOR CERTAIN INSTALLATIONS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2016 9:35:00 AM
Creation date
10/24/2016 9:34:59 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
5575
Res Ord Title
ADOPTING THE ILLINOIS STATE PLUMBING CODE AND ESTABLISHING MINIMUM STANDARDS FOR CERTAIN INSTALLATIONS
Approved Date
9/7/1971
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.' ' . <br /> . f <br /> �.,' .... <br /> � • 9 <br /> and thereon the vent connector shall be of corrosion resistant material <br /> the same size as the draft hood, strong enough to withstand damage not <br /> connected to the smoke pipe of a coal or oil furnace, made as short as <br /> possible and in no case longer than 75% of the chimney height installed <br /> with a rise toward the flue of a minimum of 1/4 inch per foot of length. <br /> Water heaters, except electrical heaters, shall be installed with suffi- <br /> cient clearance between the heater or vent connector and any nearby combus- <br /> tible material so that the temperature of such material does not increase <br /> more than 90 degrees F. above room temperature when fuel is be ing burned <br /> in said heater. Automatic gas water heaters shall be equipped with an ap- <br /> proved type safety pilot and gas pressure regulator. All water heaters <br /> shall be equipped urith a combination temperature and pressure dip tube re- <br /> lief valve installed directly into the top of the tank or into the side of <br /> the tank not more than 6 inches below the top or on the hot water outlet <br /> within three inches, of the tank and of sufficient capacity to prevent water <br /> temperature in excess of 210 degrees F. the valve whereof shall be receding <br /> with a try-lever and approved by the American Gas Association or other the <br /> recognized testing agency and capable of relief in B.T.U. of 10� over the <br /> rated input of the water heater, equipped with a discharge pipe terminating <br /> not more than 10 inches from the floor with an unthreaded end, and in new <br />' construction over an open fixture or, if in a basement or utility room, over <br /> the floor not more than 6 feet from a floor drain. <br /> Section 40. Notwithstanding any provision to the contrary in said <br /> code or in othe r ordinance, rule or re gulation of the State of Illinois or <br /> the City of Decatur, Illinois, no connection shall be made to a sanitary <br /> sewer which will permit surface or storm water drainage into said sewer, and <br /> no connection shall be made to a surface or storm water drain or se wer which <br /> will permit sanitary sewage to be admitted into such surface or storm water <br /> drain or sewer. No connection shall be made to an existing combination sewer <br /> unless evidence satisfactory in the judgment of the Director of Public Works <br /> is submitted to him to clearly show that the existing use thereof along with <br /> the additional use as a result of the proposed connection are less than sixty <br /> per cent of the capacity of the existing se wer under all reasonable condi- <br /> tions, and that there is no reasonably feasible alternative to pzovide ser- <br /> vice other than by the connection proposed. <br /> Section 41. Appeals from the orders or decisions of the Inspection <br /> Division shall be to the Constructinn Board of Appeals in the time and man- <br /> ner provided by the City Code. <br /> Section 42. In case any provision of this ordinance is found to be in <br /> conflict with a provision of any other ordinance of the city or with a pro- <br /> vision of the code adopted by this ordinance, that provision which estab- <br /> lishes the higher standard for the promotion and protection of the health <br /> and safety of the people shall prevail. This ordinance replaces Ordinance <br /> gQo. 5055, passed by the Council of the City of Decatur, Illinois, on the 19th <br /> day of August, 1968, and all amendments thereto since said day to the effec- <br /> tive date hereof which said ordinance and amendments be, and the same are <br /> here by, repealed along with those parts and provisio ns of other ordinances <br /> existing on the effective date hereof which are in conflict herewith which <br /> are to the extent of such conflict only here by repealed. <br />
The URL can be used to link to this page
Your browser does not support the video tag.