i
<br /> Q.I;;.,,F,A1A
<br /> Document A101 TM - 2007
<br /> Standard Form of Agreement Between Owner and Contractor where the basis of
<br /> payment is a Stipulated Sum
<br /> AGREEMENT made as of the 22nd day of November in the year 2016
<br /> (In words, indicate day,month and year.) ADDITIONS AND DELETIONS:
<br /> The author of this document has
<br /> BETWEEN the Owner: added information needed for its
<br /> (Name, legal status, address and other information) completion.The author may also
<br /> have revised the text of the original
<br /> City of Decatur AIA standard form.An Additions and
<br /> 1 Gary K Anderson Plaza Deletions Report that notes added
<br /> Decatur,Illinois 62523 information as well as revisions to
<br /> Telephone Number:217-424 2702 the standard form text is available
<br /> from the author and should be
<br /> reviewed.A vertical line in the left
<br /> and the Contractor: margin of this document indicates
<br /> (Name, legal status, address and other information) where the author has added
<br /> necessary information and where
<br /> the author has added to or deleted
<br /> Felmley-Dickerson Co.
<br /> 401 E.Lafayette St. from the original AIA text.
<br /> Bloomington,Illinois 61701 This document has important legal
<br /> 309-828-4317 consequences.Consultation with an
<br /> attorney is encouraged with respect
<br /> for the following Project: to its completion or modification.
<br /> (Name, location and detailed description) AIA Document A201 Tm-2007,
<br /> General Conditions of the Contract
<br /> Decatur Fire Department Renovation Work for Construction,is adopted in this
<br /> document by reference.Do not use
<br /> Project consists of the Renovation work to Fire Stations#1,#2,#4,. with other general conditions unless
<br /> this document is modified.
<br /> Fire Station#1:
<br /> 1)General Construction Work:Masonry work that includes correcting water infiltration
<br /> by installing masonry thru wall flashing at existing roof to wall terminations and thru
<br /> wall flashing investigation at base of wall and other locations. Miscellaneous door and
<br /> hardware replacement.Replacement of bathroom countertops.
<br /> 2)Plumbing Work:Replacement of plumbing equipment including drinking fountains,
<br /> flush valves,water heater,recirculating pump,thermostatic mixing valves,faucets,and
<br /> shower heads.Also includes reworking sanitary waste line in basement for positive flow
<br /> and installing a grease trap for the kitchen.
<br /> 3)Sprinkler Work:None.
<br /> 4)Heating,Ventilating and Air Conditioning Work:Adjustment to duct work in
<br /> basement for sanitary waste line work.
<br /> 5)Electrical Work:Replace existing exterior light fixture and add surge protection.
<br /> 6)Technology:Modifications and upgrades to the following systems:Horizontal
<br /> structured cabling system including new telecommunications outlets,cabling,patch
<br /> panels,and connectivity for support of voice/data/network devices. Wired and wireless
<br /> LAN including access points,cabling,and network switches.Audio/Visual presentation
<br /> systems for conference and training facilities.CAD Display monitoring system. Cable
<br /> management including conduit,back boxes,and surface mount raceways for support of
<br /> existing and new low voltage systems.
<br /> Fire Station#2:
<br /> Init. AIA Document A101 TM—2007.Copyright©1915,1918,1925,1937,1951,1958,1961,1963,1967,1974,1977,1987,1991,1997 and 2007 by The American
<br /> Institute of Architects.All rights reserved.WARNING:This AIA® Document is protected by U.S.Copyright Law and International Treaties.Unauthorized 1
<br /> reproduction or distribution of this AIA® Document,or any portion of it,may result in severe civil and criminal penalties,and will be prosecuted to
<br /> the maximum extent possible under the law.This document was produced by AIA software at 14:52:24 on 11/18/2016 under Order No.4982744446_1 which
<br /> expires on 07/01/2017,and is not for resale.
<br /> User Notes: (1514818386)