My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
R2020-119 Resolution Authorizing City of Decatur Supplement #1 to the Professional Engineering Services Agreement Between the City of Decatur and AECOM for Design Services for the Improvement of Brush College Road over Faries Parkwa
COD
>
City Clerk
>
RESOLUTIONS
>
2020
>
R2020-119 Resolution Authorizing City of Decatur Supplement #1 to the Professional Engineering Services Agreement Between the City of Decatur and AECOM for Design Services for the Improvement of Brush College Road over Faries Parkwa
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 12:46:47 PM
Creation date
9/14/2020 10:45:22 AM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
R2020-119
Res Ord Title
R2020-119 Resolution Authorizing City of Decatur Supplement #1 to the Professional Engineering Services Agreement Between the City of Decatur and AECOM for Design Services for the Improvement of Brush College Road over Faries Parkway
Department
Public Works
Approved Date
9/8/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Exhibit A-Supplement 1 <br /> Drainage Modeling Analysis and Study-Proposed <br /> During preparation of the Drainage Memorandum it was determined that the existing storm sewer system <br /> along East Harrison east leg is undersized. This section of storm sewer was not within the current project <br /> limits. It was determined that an update to this section of storm sewer would be beneficial to the project and <br /> to include this work in the project. WHKS has been assigned the drainage design and memorandum work <br /> and will add this section of storm sewer. Finalize drainage calculations for new section along East Harrison. <br /> Additional cost by WHKS are presented for Drainage Design work_ <br /> Utility Coordination(only item IOf, 1 Ih,and 13c from original scope shown here for additional scone <br /> discussion <br /> 10. Coordination with Norfolk Southern <br /> f. Prepare and submit bore and jack application with fee and plans to Norfolk Southern <br /> (nspipeandwire.com). It is assumed the City will enter into the permanent agreements and pay <br /> the required fees when the applications are submitted. NS has increased the permit process <br /> requirements. It now requires additional items be submitted with the application. Additional <br /> hours are presented for NS RR permit preparation work.Additional Geotechnical field and <br /> report work not presented at this time until further discussions with City and Geotechnical <br /> subconsultant. <br /> 11. Coordination with(IC RR) <br /> h. Prepare and submit bore and jack application with fee and plans to(IC RR). It is assumed the <br /> City will enter into the permanent agreements and pay the required fees when the applications <br /> are submitted.IC RR(CN)has increased the permit process requirements. It now requires <br /> additional items be submitted with the application. Additional hours are presented for IC RR <br /> permit preparation work.Additional Geotechnical field and report work not presented at this <br /> time until further discussions with City and Geotechnical subconsultant. <br /> 13. Coordination with City of Decatur <br /> c. Prepare Water Line Relocation Plans and IEPA Permits. Additional water main relocation not <br /> identified in Phase I was determined through coordination with the structural group at the center <br /> pier location on Faries Parkway. Additional hours are presented for Phase II watermain design <br /> and relocation plan and quantity work. <br /> Assumptions made for Water and Sanitary Sewer Relocation: (only items 1, 7, 8,and 9 from original scope <br /> shown here for additional scope discussion) <br /> 1. The original hours and fee estimate proposal was based on the relocation of approximately 2,000 feet <br /> each of 24"and 16"water mains(4,000 feet total)and approximately 1,000 LF of sanitary sewer. <br /> These two lines were the ones running north south on Brush College Road. The east west line on <br /> Faries Parkway was not identified as in conflict with the bridge pier in Phase I document used for <br /> original scope and manhour preparation. See Utility Coordination City Decatur above. This <br /> relocation will involve a new utility crossing under the IC RR as the existing crossing location <br /> cannot be used. See Utility Coordination IC RR above. <br /> 7. Any soil borings or Geotech reports required for the water main design and/or the railroads involved <br /> are not included at this time in the original proposal. A current download of the Railroad Utility <br /> Crossing Permit now requires a Geotechnical Report(PGR). See Utility Coordination NS and IC <br /> RR above.Additional Geotechnical field and report work not presented at this time until further <br /> discussions with City and Geotechnical subconsultant. <br /> 8. The original scope proposal does not include providing any of the possible permitting requirements <br /> by railroads such as dewatering plan/vibration monitoring/shoring plan/settlement monitoring, etc.A <br /> current download of the Railroad Utility Crossing Permit now requires a Dewatering Plan,a <br /> Vibration Monitoring Plan,and a Settlement Monitoring Plan. See Utility Coordination NS and IC <br /> RR above. <br /> Additional Scope 08-21-20 ExA SI-6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.