R2022-109 Resolution Authorizing Agreement with Concentric Integration, LLC for South Water Treatment Plant PLC Upgrades Phase I City Project 2022-32
COD
>
City Clerk
>
RESOLUTIONS
>
2022
>
R2022-109 Resolution Authorizing Agreement with Concentric Integration, LLC for South Water Treatment Plant PLC Upgrades Phase I City Project 2022-32
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2022 4:03:29 PM
Creation date
7/6/2022 4:03:20 PM
Metadata
Fields
Template:
Resolution/Ordinance
Res Ord Num
R2022-109
Res Ord Title
R2022-109 Resolution Authorizing Agreement with Concentric Integration, LLC for South Water Treatment Plant PLC Upgrades Phase I City Project 2022-32
Department
Public Works
Approved Date
7/5/2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C141 <br /> CONCENTRIC <br /> INTEGRATION <br /> a. Migrate existing SCC1 SLC logic,SCC6 Micrologix logic,and SCC1C ControlLogix logic into 1 single 1756- <br /> L83E controller. <br /> b. Migrate existing Panelview Plus 6 screens on SCC1C into a Panelview 5000 application. <br /> c. Create Critical Alarm tags for Panelview 5000. <br /> 2. SCADA programming <br /> a. Update iFix 10 Tags for the telemetry system to read from SCC1C instead of SCCI <br /> b. Update iFix 10 tags for SCC1,SCC1A,and SCC6 SCADA tags to communicate with new processor <br /> c. Update iFix Alarm tags for SCC1,SCC1A,and SCC1C. <br /> Installation <br /> 1. Install serial to Ethernet bridge into existing SCC1C control panel <br /> 2. Install upgraded PLC processor into existing SCC1C control panel <br /> 3. Provide removal of existing SCC1,SCC1A,and SCC6 control panels <br /> 4. Install new control panel <br /> 5. Install new Termination Extension Panel <br /> 6. Install new Panelview 5000 in existing SCC1C control panel <br /> Startup <br /> 1. Telemetry Startup <br /> a. Provide startup and testing for the relocated telemetry logic and SCADA control. <br /> b. Prior the removal and installation of the new control panel,the telemetry system migration must be <br /> completed. <br /> 2. Control Panel Startup <br /> a. Provide startup and testing of the new control panel(s)and SCADA control. <br /> Option 1 Spare Parts <br /> a. Qty one(1)Allen Bradley 1756-PA75 PLC Power Supply <br /> b. Qty one(1)Allen Bradley 1756-IB16 DC digital input card <br /> c. Qty one(1)Allen Bradley 1756-OW161 relay output cards <br /> d. Qty one(1)Allen Bradley 1756-IF161H isolated analog input cards <br /> e. Qty one(1)Allen Bradley 1756-OF81 isolated analog output cards <br /> f. Qty one(1)Allen Bradley 1756-AI16120VAC digital input cards <br /> g. Qty one(1)Allen Bradley 1756-EN2T Communications Module <br /> Project#212493 Paoe IV°•' <br />