FRONTLINE <br /> COMMUNICATIONS Decatur Police Department <br /> 'Division <br /> °'Phone <br /> Nanu°"""n9JM010""""'"°°n`ion'torsion. Crisis Negotiation Vehicle Proposal <br /> Wiring Identification <br /> All line voltage conductors located in the main panel board will be individually and permanently <br /> identified. The identification will reference the wiring schematic or indicate the final termination <br /> point. When prewiring for future power sources or devices,the unterminated ends will be labeled <br /> showing function and wire size. <br /> Wet Locations <br /> All wet location receptacle outlets and inlet devices, including those on hardwired remote power <br /> distribution boxes, will be of the grounding type provided with a wet location cover and installed <br /> in accordance with Section 210-7 "Receptacles and Cord Connections" of the NEC. <br /> All receptacles located in a wet location will be not less than 24.00" (610 mm) from the ground. <br /> Receptacles on off-road vehicles will be a minimum of 30.00" (762 mm) from the ground. <br /> The face of any wet location receptacle will be installed in a plane from vertical to not more than <br /> 45 degrees off vertical. No receptacle will be installed in a face up position. <br /> Dry Locations <br /> All receptacles located in a dry location will be of the grounding type. Receptacles will be not less <br /> than 30.00" (762 mm)above the interior floor height. <br /> All receptacles will be marked with the type of line voltage(120-volts or 240-volts)and the current <br /> rating in amps. If the receptacles are direct current, or other than single phase, they will be so <br /> marked. <br /> Listing <br /> All receptacles and electrical inlet devices will be listed to UL 498,Standard for Safety Attachment <br /> Plugs and Receptacles, or other appropriate performance standards. Receptacles used for direct <br /> current voltages will be rated for the appropriate service. <br /> Electrical System Testing <br /> The wiring and associated equipment will be tested by the apparatus manufacturer or the installer <br /> of the line voltage system. <br /> The wiring and permanently connected devices and equipment will be subjected to a dielectric <br /> voltage withstand test of 900-volts for one (1) minute. The test will be conducted between live <br /> parts and the neutral conductor,and between live parts and the vehicle frame with any switches in <br /> the circuit(s)closed. This test will be conducted after all body work has been completed. <br /> Electrical polarity verification will be made of all permanently wired equipment and receptacles <br /> to determine that connections have been properly made. <br /> Bid#253 Page 19 Printed:5/11/2026 <br />