Laserfiche WebLink
Exhibit A <br /> REPORT <br /> T.V. INSPECTION <br /> A PACP Certified report database will be provided documenting the techniques and equipment <br /> used and summarizing the inspection. The database will include the following: <br /> 1. Separate pages for each run or line noting distances and locations of the <br /> following: <br /> -Any structural damage, cracks, broken pipe, etc. <br /> -All service tie-ins and type <br /> -Manhole numbers <br /> -Direction of flow/depth <br /> -Depth and type of debris <br /> -Type of pipe and size <br /> -Color photos of problem areas <br /> 2. Evaluation of existing conditions found <br /> 3. MPEG/Digital <br /> -Complete on screen data view showing project name,date,continuous <br /> footage to nearest 0.10 ft.from starting manhole number. <br /> -Narration explaining conditions as seen. <br /> MANHOLE INVESTIGATION/EVALUATION <br /> I. Separate form for each manhole showing the following data in a MACP format <br /> downloaded to city mainframe, for use with Department E& I's current ESRI <br /> software: <br /> -All dimensions of the manhole <br /> -All sewer line tie-ins and sizes <br /> -Direction of flow/depth <br /> -Depth and type of debris <br /> -Location and type of defects <br /> -Environmental conditions,water and atmosphere temperatures <br /> -Evaluation of existing conditions found <br /> -Video of the MH in MPEG format <br /> A-2 <br /> Last Revised:05/30/2013 <br />