Laserfiche WebLink
Decatur,City of,Mound School Bodine Project#114675 <br /> Phase II Subsurface Investigation Report August 29 2003 <br /> containers. Sample containers were immediately sealed, labeled and placed into a cooler <br /> containing blue ice. Sample identification number correspond directly with the boring <br /> locations indicated on Figure 1. <br /> On July 28, 2003,the samples were relinquished to PDC Laboratories, Inc. courier under <br /> the Chain of Custody. Samples arrived at the laboratory and were logged into the <br /> laboratory system on August 28, 2003. Pursuant to the Service Agreement,the <br /> laboratory conducted the analysis of the samples for BTEX and PAHs. Bodine received <br /> the laboratory report, with the original Chain of Custody on August 13, 2003, see <br /> Attachment B. <br /> 3.3 Data Review: <br /> Bodine completed a review of the data for samples B3,B5, B6, B8, B9 and B11. All <br /> samples for BTEX and PAH compounds were reported by the laboratory as not detected <br /> at the laboratory reporting limit. The laboratory report, Attachment B, indicates <br /> reporting limits and concentrations for both dry weight and wet weight measurements. <br /> According to regulatory guidelines, sample results reported as dry weight are to be used <br /> to compare to the IEPA TACO Soil Remediation Objectives (SROs). Bodine has <br /> included a Table 1 summarizing the laboratory reported concentrations. <br /> The laboratory reported qualifications in samples identified as B3, B8 and B9. <br /> Qualifications for Benzene reported concentrations below the reporting limit were <br /> indicated to have surrogate recoveries which failed to meet the required acceptance <br /> criteria in the initial analysis. The samples were re-extracted beyond the maa�imum <br /> allowable holding time and re-analyzed. The surrogate recovery for the second analysis <br /> was also outside the required acceptance criteria. The results should be interpreted as <br /> estimated concentrations. However,the estimated concentrations should be biased high <br /> and the actual concentration would be lower than the reported value. <br /> Sample B3 was also qualified with a R value for the Indeno(1,2,3-cd)pyrene compound. <br /> This qualification indicates the analyte failed to meet the required acceptance criteria for <br /> relative percent difference (RPD)between the Matrix Spike and Matrix Spike Duplicate <br /> (MS/MSD). The reported sample concentration should be considered usable at the <br /> reported value. The correlation between the laboratory's internal standards does not <br /> affect the quality of the reported data and may be a direct result of matrix effects. <br /> 3.4 Findings & Conclusions: <br /> Based upon review of the laboratory reported concentrations for BTEX and PAH <br /> analysis, Bodine finds that all locations indicate concentrations below the laboratory <br /> reporting limits and below the IEPA TACO Tier 1 SROs. The laboratory reported <br /> concentrations do not indicate a release has occurred. <br /> 4 <br /> BUnINE�NVIRONMENTAI SERVICES, INC. <br />