Laserfiche WebLink
, � 0� Develope�Guide, Edition 2.2 <br /> � � ` c. Naturai Resources: <br /> The presence of speciflc natural resources to be reviewed include wetlands and critical habitat / <br /> endangered species. Specifically, the consultant is requested to review certain documents and to <br /> make direct contact with certain public agencies. Comments regarding the potential for wetlands to <br /> be present at a site will be based on a review of the National Wetland Inventory Maps, as well as site <br /> reconnaissance observations. Review of the potential for critical habitaUendangered species to be <br /> present will involve contacting the State and Federal Fish and Wldlife Services and National Marine <br /> Fisheries Services as required, as well as other relevant state and local agencies. The consultant is <br /> requested to provide either a copy of a telephone log or correspondence from the appropriate agency. <br /> d. Cultural Resources: <br /> The Consultant is requested to review documents or make direct contact with the applicable local <br /> historic societ�t or State Historical Preservation Office (SHPO) regarding possible historical <br /> significance or impacts to the site. An opinion should be provided in the report conceming the <br /> potential archeological significance and the need for further field determination or investigation. <br /> e. Site Inspection: <br /> The purpose of the site inspection is to look for physical evidence of environmental risk on or near the <br /> site. The effectiveness of the site inspection depends on the knowledge and experience of the <br /> individuals assigned to pertorm the work They must be able to detect subtle symptoms of potential <br /> problems. Target therefore, expects that an expenenced Consultant who is familiar with the resu/ts of <br /> the historical review wil!conduct the site reconnaissance. <br /> Target has developed the following"minimum guidelines"covering six particularly sensitive areas: <br /> 1) PCBs: The Consultant should: <br /> a) Check inside and outside any buildings for transformers, capacitors or light fixture ballasts; <br /> b) Check for equipment using hydraulic fluid, which cou�d contain PCB's; <br /> c) Check for visible signs of damage to the equipment, seeps or weeps; <br /> d) Note whether transformers are on pads or curbed; <br /> e) Note PCB labels and identification numbers; and, <br /> � Check for visible or documented evidence of PCB contamination. <br /> If any of the above is found on the site,the Consultant should contact the responsible utility company <br /> or operator for dates of manufacture, dates of installation, and PCB concentration of fluids. The <br /> location of known or suspected PCB-containing equipment must be identified on the site map in the <br /> appendix to the Phase I Report Photographs of the equipment should be taken. <br /> 2) Underqround Storaqe Tanks (US'n /Aboveqround Storaqe Tanks (AS'I�: The Consultant should <br /> review the information obtained during the historical review before visiting the site to determine <br /> whether there is any evidence that UST / AST are or were located on the site or on nearby <br /> properties. As part of the on-site inspection, the Consultant should: <br /> a) Assess current on-site activities that require the use or storage of regulated substances, <br /> including the type of heating systems and fuel source; <br /> b) Assess previous site activities associated with the use of tanks, e.g., gas stations or <br /> automotive service facilities; � <br /> c) Check for visible evidence of past or present use of UST /AST (e.g., fill pipes, vent pipes, <br /> abandoned fill caps, stained soils, stressed vegetation, or evidence that a tank has been <br /> removed, such as uniformly settled or slumped areas, patched paving or concrete pads); and, <br /> d) Determine if tanks located on the property are registered and obtain the following information <br /> for each tank: owner, operator, tank capacity, substance stored, installation date, corrosion <br /> protection, leak protection, fill records, and results of leak detection tests. <br /> 3) Hazardous Materials: Hazardous materials include, but are not limited to the following: asbestos <br /> containing materials, lead-based paint or sealers, fluorescent light bulbs, mercury switches, freon <br /> containing appliances or equipment, landfills, pits and sumps, chemicals and raw materials, etc. <br /> If hazardous materials are stored or used on the site, the Consultant shoutd: <br /> a) Identify all containers holding significant quantities of hazardous material noting the type(s) of <br /> container(s), the condition of the container(s), the number of each type of container, the <br /> contents of each container, the manufacturer and any other information on any labels; <br /> b) Obtain Material Safety Data Sheets (MSDS) from the owner or ope�ator for hazardous <br /> materials stored on the site, if available; <br /> c) Verify that hazardous materials are stored in a secured area away from water supplies, <br /> drains, and other pathways that could contaminate the environment and/or note questionable <br /> practices; and, <br /> 3.19 <br />