. � .�,'� . <br /> mit the same to be connected in such manner as to prevent the escape of <br /> liquid other than into the tank being filled, and also in such manner that <br /> the flowage of liquid will automatically cease when the tank being filled <br /> is filled to 99.25� of its capacity. No delivery or transfer of Class I <br /> or II flammable liquid into the tanks of marketing or service station shall <br /> be aade except throu gh such connection as required hereby. No tank or caoi- <br /> partment uf a transporting aehicle, or any storage tank or compartment shall <br /> be filed with Class I or II flammable liquid in excess of 99.259b of the capa- <br /> city thereof. During the making and breaking of cc�nnections, the motors of <br /> delivering vehicles shall be sh�at dov�. <br /> 10. Undergronnd flaamable liquid storage tanks shall be so maintained <br /> so as to sustain a pressure of not less than 5 pounds per square inch of <br /> either hydrostatic or air pressure upon the testing thereof. The owner, or <br /> operator, of each such tank shall cause the same to be tested at least once <br /> every three years in the presence of a representative of the Fire Depaxtment <br /> of the City and under the supervision thereof. The testing procedure to be <br /> followed is that a�iich is provided for in the Recommended Practice On Under- <br /> ground Leakage Of Flammable and Combustible Liquids promulgated and published � <br /> in the National Fire Oodes of the National Fire Protection Association as ', <br /> N.F.P,A. No. 329. 1Yansfer of flamnable liquid sha11 be made into such a tank �, <br /> only wd�en the same has been certified by said Department to have been properly II <br /> and successfully tested on a date �ithin three yeaxs of the date of delivery. � <br /> No such transfer shall be made into a tank which has been found defective and <br /> is so posted by said Department. If tY�e owr�er, or operator, of such a tank is <br /> notified that the sa�e is defective said ownex, or operator, shall without de- <br /> lay cause the tank to be voided of liquid and sha11 cease use and operation of <br /> the same until the same is made non-defective. Such a defective tank if not <br /> repaired arithin 9� days from such notification shall constitute an abandonment <br /> the r eof. <br /> 11. No underground flammable liquid storage tank shall be maintained as <br /> "temporarily out of ser�ice" for a continueus period of more than 90 days ex- <br /> cept upon application to the Fire Department and the extension of said period <br /> thereby which extension shall in no event e xtend said original period longer <br /> than one additional period of 90 days. <br /> 12. After the effective date of this provision, no underground flammable <br /> liquid storage tank shall be abandoned in place within the City. After said <br /> date all such tanks shall within 90 days after the use or operation thereof is <br /> terminated, subject to the provisions of sectiAn 11 of this Chapter, shall be <br /> removed as provided by Appendix B of said Fire Prevention Oode. <br /> 13, An undergxound flammable liquid storage tank aban�ned in place be- <br /> fore the effective date of this provision which has heretofore been voided oP <br /> all flamffiable liquid and fumes; had all suction, inlet, gauge and vent lines <br /> disconnected and all remaini.ng underground piping capped; and said tank filled <br /> completely with an inert solid material may remain in place. Any such tank <br /> abandoned in place before said date but not so voided, said lines or piping <br /> discannected and capped, or not so filled completely with inert solid matexial <br /> shall be caused to be removed by the ov�aie r of the premises �ereon the same <br /> exists in the nanner provided in said Appendix B, within 60 days after the gi�- <br />