Laserfiche WebLink
. , �, . <br /> � � <br /> . Chapt�r 43.1 <br /> The fire wall shall be so ccrostructed as to remain structurally in place <br /> against an exterior exposing fire for the daration of ti�e indicated in the <br /> table, and if said vaa11 is adjacent to a flat roof it �hall be constructed <br /> with a parapet and a roof covering of at least Class C shall be provided, <br /> and if the same is adjacent to a sloped roof it shall be e�ctended to the <br /> underside of the Yoof sheathing and a roof covering of at least Class B <br /> sha11 be provid�d. <br /> 9. In the fire limits stor� enclosures which do not project more than <br /> six feet beyond the building line may be of frame construction not more than <br /> ten feet in height and not more than three feet wideY than the doors the <br /> same serve. <br /> 10. All roof coverings hereafter provided in the fire limits sha].l be <br /> of BOCA Code Class A, B or C ratings complying with Article 9 thereof. <br /> 11. Wher; the same are to l� emplaced, used temporarily for a limited <br /> pexiod of time as approved by the building official and then removed, builder's <br /> shanties in conneatiron with approved building aperations, platforns, reviewing <br /> stands and other similar stzuctures �ay be of fra�ae construction. <br /> 12. Upon the cc�di.tions and limitations se� out with re�pect thereto as to <br /> each, the following ma,y be constructed within the fire limitsr <br /> a. Timber Construction. Coal and material bins, tank stzuctures and <br /> tYestles of mi11 type heavy timber construction with dimensions not less than <br /> that required for �OCA Code Type 3A, not over thirty-five feet in height when <br /> located not less than thixtq feet fro�a interior lot lines and from any build- <br /> ing, e�ecept when located on lot Iines along a railroad right-of-way. ' <br /> b. Erection on Buildings. Aerial sapports not more than twr:lve geet <br /> in height, water tanks and flag poles made of wc�od on buildings not more than <br /> three stories or more than forty feet, or either, in height, and woc�den drip <br /> bars in cooling towers. <br /> c. Motoz Fuel Sexvice Stations. Gasoline service stations and struc- <br /> tures of si�eilax business uses exc7.uding high hazard use� may be con�txucted of <br /> BOCA Code uxzprotected x�on-combustible lype C2 constxuction within the height and <br /> area limits of Group fi oP table 6 provided they are located not less than eleven <br /> feet from any lot line and from asry building, <br /> d. Bus an d Passenger Terainal�. Rc�ofs over parking lots, bus and <br /> passenger terminals may be constructed not over one story or twenty feet, or either, <br /> in height and not more than eleven thou�and square feet in area of HOCA Oode non- <br /> ccymbustible Type �C, oz of heavy timbex mill Type 3A construction. <br />